background image

Care and Maintenance

Your LPG Portable Water Heater has a metal casing and a stainless Steel face 

plate and so, should be cleaned after each use. This will not only maintain the 

appearance of your Gas Hot water Shower, it will also add to its longevity.

Clean your LPG Portable Water Heater by following these steps:

More frequent cleaning may be necessary for coastal and tropical climates or in 

salty or corrosive environments.

Always ensure no debris is present in the flue or unit as this may cause a fire 

when use.

NOTE: 

Failure to clean your LPG Portable Water Heater adequately or failure to 

follow these cleaning instructions will void your warranty. 

The use of ABRASIVE materials and/or ALKALINE based cleaners will damage the 

LPG Portable Water Heater. Their use is strictly prohibited and will void 

your warranty.

If you are unsure of how to adequately clean and maintain your LPG Portable 

Water Heater, please contact your place of purchase for further information.

If using water other than drinking quality water ensure the pump filter 

supplied is clean before each use. 

Storage, Frost / Freezing temperatures: If the appliance is to be stored for any 

length of time or subjected to temperatures below freezing, it is necessary to 

drain any water trapped in the appliance.

1.

 Disconnect the inlet water hose.

2. 

Allow the hot water hose and shower rose to hang down.

3. 

 Loosen the screw in the water drain valve located at the bottom of the 

appliance, (near to the water inlet fitting) allowing the appliance to drain.  

Gently re-tighten the water drain screw. 

1. 

Wipe down using a pH neutral soap solution, diluted in clean water.

2. 

Only use non-abrasive fibre brushes or sponges while cleaning.

Troubleshooting

This guide should be followed in case of failure of the appliance to operate 

correctly. If symptoms persist contact Customer Service on 1800 654 767

Problem

Cause

The Appliance will not 

light at all

Make sure you have new batteries installed in the 

correct position.

Negative should be down closest to you and Positive 

towards the back. In high humidity conditions it may be 

necessary to clean and dry the battery box 

prior to operation. 

Check for sufficient water pressure. The unit must have 

a minimum of 25KPA of sustained pressure to activate 

the burners.
There may be debris within the water inlet. Remove 

connections to the inlet and inspect. Remove any de-

bris that may be blocking the unit and retry.
The gas line may need purging. Turn gas to maximum 

and burners to High on the unit and turn the water on/

off a few times.

Check that water is flowing through correctly. Make 

sure “Water In” is on the right and “Water Out” is in 

the middle.
Make sure the On/Off switch is turned on, do this by 

having the Red dot pushed in.
If unit fails to ignite when LED display lights and ignition 

is clicking.

1. Disconnect all gas attachments from the unit and 

gas bottle.

2. Re-connect your gas line to the unit including all tape 

and washers (do not turn the gas on).

3. Turn your water supply on.

Once the unit starts to click, turn your gas bottle on 

slowly and watch for ignition through the window.

Water flows through, but 

the unit will not get hot

New batteries may be required for the ignition switch. 

Verify that the batteries are aligned in the proper 

polarity (+/-). Check the battery case.
Check that the water pressure is at least 25 kPa to 

activate the burners.
Make sure there is an adequate amount of gas in your 

bottle.

Check that water is flowing through correctly. Make 

sure “Water In” is on the right and “Water Out” is in the 

middle.
Try the unit on mains water if possible, if this works, there 

is an issue with the pump. Please make sure your pump 

meets requirements.

| Gas Hot Water Shower

|Gas Hot Water Shower

Page 17

Page 18

Summary of Contents for 78X04

Page 1: ...78X04 ...

Page 2: ... please read this manual carefully before using Retain this manual for future reference for installation and warranty Table of contents Product Information Safety Instructions Performance Specifications Set Up Operation Care and Maintenance Trouble Shooting Technical Assistance Warranty 1 3 4 7 9 11 17 18 19 20 ...

Page 3: ...pictures shown in the figures in this handbook are purely indicative Do not use the appliance if it has a leak or has worn deteriorated or damaged seals Accessible parts may be very hot Keep young children away It may be hazardous to attempt to fit other types of gas containers or cartridges This appliance is to be stored in a dry well ventilated location free from direct sunlight Do not store whe...

Page 4: ...rom above to all combustible surfaces fabrics flammable materials people The appliance is designed to be hung upright against a non combustible vertical surface Do not operate from a non upright position Doing so can be dangerous and will damage the appliance During operation ensure that air inlets and the top exhaust are kept free from obstructions and closure Important This appliance is designed...

Page 5: ...to the gas cylinder If being stored indoors ensure that the location complies with AS NZS 1596 WARNING It is hazardous to attempt to fit other types of gas containers Connect and change cylinders in a well ventilated location preferably outside away from people and any sources of ignition such as naked flames pilot flames electric heaters equipment List of Parts Supplied 1 x LPG Portable Water Hea...

Page 6: ... Horizontal with conical face up Inlet Connection POL Fitting with Left Hand thread Size mm 35 x 75 x 1630 hose included Weight kg 0 45 Model Number FL 022 Power Supply V DC 12 Power Demand Amps 3 5 Pump Type Diaphragm Pump Pressure PSI 35 Flow Rate l m 4 3 Size mm 185 x 110 x 65 Weight kg 0 67 Max Flow Rate l m 6 Heat Exchanger Limited Flow Restriction On Off Switch Flow Variations 4 Dimensions m...

Page 7: ...to the outlet side of the pump Use a hose clamp to fix hose to pump Attach other hose to inlet of pump with hose clamp See Page 15 for more details 9 Fit seal to chrome flexible shower hose then attach hexagonal end to the water out connection middle connection on the water heater Do not over tighten Seal Clear rubber washer Ensure a seal supplied is inserted into the connector at both ends of the...

Page 8: ...otice the positioning of the gas cylinder away and to the side of the appliance never place the gas cylinder directly beside or above the appliance 2 Connect the Gas Hose to the POL Propane gas cylinder Hand tighten the connection in an anti clockwise direction Open gas tap on cylinder one full turn and then check the connections for leaks with soapy water DO NOT use a flame If a leak is detected ...

Page 9: ...Switch the TEMPERATURE CONTROL from MIN to MAX will increase the temperature further A temperature in excess of 50 C will activate the Over Temperature Safety Sensor and will shut down the burners To relight the burner you will need to either Turn the switch off on the unit and allow cool water to flow through the unit until it drops the internal temperature low enough to reignite the burner Turn ...

Page 10: ... or fail b Be careful to properly route and secure all wiring c Fuse appropriately d Toggle switch with adequate amp rating is required to allow for ON OFF operation b Using a hose clamp supplied connect the 1 5m length of fresh water hose with crimped swivel fitting from the pump outlet to the Gas Hot Water Shower Important The pump must be NOT be installed with the motor facing downwards WARNING...

Page 11: ...f the appliance to operate correctly If symptoms persist contact Customer Service on 1800 654 767 Problem Cause The Appliance will not light at all Make sure you have new batteries installed in the correct position Negative should be down closest to you and Positive towards the back In high humidity conditions it may be necessary to clean and dry the battery box prior to operation Check for suffic...

Page 12: ...e from defects in workmanship and materials for the warranty period 2 Fitting and use Please ensure you a fit the Kingsley product in accordance with the product information and all relevant vehicle safety and compliance laws b use the Kingsley product for the purpose for which it was originally designed and in accordance with the product information and all relevant vehicle safety and compliance ...

Page 13: ...bushranger com au Free Call 1800 654 767 Australia only International 61 2 8700 0400 Fax 61 2 8700 0499 Email sales kingsleyenterprises com au Address 6A Brooks Road Ingleburn NSW 2565 ...

Reviews: