Set Up

Before using the appliance, it is important to prepare the appliance by installing 

the proper adaptors to suit our intended use. In this example, we will be preparing 

the portable water heater to be used with a hose input from a 12-volt pump.

1. 

Remove the heater along with all the 

components from the box and place 

them on a table. Notice that there is a 

gas input, hot water output, cold water 

input as well as a battery box.

5. 

Fit and tighten the hose fitting with a 

spanner, taking care not to over tighten 

as this could break or crack the inlet 

pipe. The ‘gas input’ is now ready to be 

connected to the gas regulator hose.

7. 

Tighten the hose, taking care not 

to over tighten as this could break or 

crack the inlet pipe.

10. 

Attach the shower rose to the 

flexible shower hose using the conical 

end fitting. Hand force only. Do not 

over tighten.

8. 

Connect free end of Water Hose 

to the outlet side of the pump. Use a 

hose clamp to fix hose to pump. Attach 

other hose to inlet of pump with hose 

clamp. See Page 15 for more details. 

9. 

Fit seal to chrome flexible shower 

hose, then attach hexagonal end to 

the ‘water out’ connection (middle 

connection) on the water heater. Do 

not over tighten.

Seal (Clear rubber washer):   

Ensure a seal (supplied) is inserted into 

the connector at both ends of the 

flexible shower hose.     

6. 

Attach black inlet hose to unit via 

crimped swivel fitting. Ensure a seal is 

inserted into the fitting.

3. 

Locate the Gas Hose and Regulator. 

It requires a black rubber seal to be 

inserted into the end shown below. 

Seal (Black

Rubber Washer)

Seal (Black

Rubber Washer)

Seal (Clear 

Rubber Washer)

Seal (Black rubber washer): 

Seal (Black rubber washer): 

4. 

DO NOT USE TEFLON TAPE on the 

gas or water fittings. The unit has been 

designed to be assembled with the use 

of rubber washers.    

2. 

Insert two ‘D’ batteries into the 

‘battery box’ and close the battery box 

lid. Note: The orientation of the battery 

terminals.

On/Off

| Gas Hot Water Shower

|Gas Hot Water Shower

Page 9

Page 10

Summary of Contents for 78X04

Page 1: ...78X04 ...

Page 2: ... please read this manual carefully before using Retain this manual for future reference for installation and warranty Table of contents Product Information Safety Instructions Performance Specifications Set Up Operation Care and Maintenance Trouble Shooting Technical Assistance Warranty 1 3 4 7 9 11 17 18 19 20 ...

Page 3: ...pictures shown in the figures in this handbook are purely indicative Do not use the appliance if it has a leak or has worn deteriorated or damaged seals Accessible parts may be very hot Keep young children away It may be hazardous to attempt to fit other types of gas containers or cartridges This appliance is to be stored in a dry well ventilated location free from direct sunlight Do not store whe...

Page 4: ...rom above to all combustible surfaces fabrics flammable materials people The appliance is designed to be hung upright against a non combustible vertical surface Do not operate from a non upright position Doing so can be dangerous and will damage the appliance During operation ensure that air inlets and the top exhaust are kept free from obstructions and closure Important This appliance is designed...

Page 5: ...to the gas cylinder If being stored indoors ensure that the location complies with AS NZS 1596 WARNING It is hazardous to attempt to fit other types of gas containers Connect and change cylinders in a well ventilated location preferably outside away from people and any sources of ignition such as naked flames pilot flames electric heaters equipment List of Parts Supplied 1 x LPG Portable Water Hea...

Page 6: ... Horizontal with conical face up Inlet Connection POL Fitting with Left Hand thread Size mm 35 x 75 x 1630 hose included Weight kg 0 45 Model Number FL 022 Power Supply V DC 12 Power Demand Amps 3 5 Pump Type Diaphragm Pump Pressure PSI 35 Flow Rate l m 4 3 Size mm 185 x 110 x 65 Weight kg 0 67 Max Flow Rate l m 6 Heat Exchanger Limited Flow Restriction On Off Switch Flow Variations 4 Dimensions m...

Page 7: ...to the outlet side of the pump Use a hose clamp to fix hose to pump Attach other hose to inlet of pump with hose clamp See Page 15 for more details 9 Fit seal to chrome flexible shower hose then attach hexagonal end to the water out connection middle connection on the water heater Do not over tighten Seal Clear rubber washer Ensure a seal supplied is inserted into the connector at both ends of the...

Page 8: ...otice the positioning of the gas cylinder away and to the side of the appliance never place the gas cylinder directly beside or above the appliance 2 Connect the Gas Hose to the POL Propane gas cylinder Hand tighten the connection in an anti clockwise direction Open gas tap on cylinder one full turn and then check the connections for leaks with soapy water DO NOT use a flame If a leak is detected ...

Page 9: ...Switch the TEMPERATURE CONTROL from MIN to MAX will increase the temperature further A temperature in excess of 50 C will activate the Over Temperature Safety Sensor and will shut down the burners To relight the burner you will need to either Turn the switch off on the unit and allow cool water to flow through the unit until it drops the internal temperature low enough to reignite the burner Turn ...

Page 10: ... or fail b Be careful to properly route and secure all wiring c Fuse appropriately d Toggle switch with adequate amp rating is required to allow for ON OFF operation b Using a hose clamp supplied connect the 1 5m length of fresh water hose with crimped swivel fitting from the pump outlet to the Gas Hot Water Shower Important The pump must be NOT be installed with the motor facing downwards WARNING...

Page 11: ...f the appliance to operate correctly If symptoms persist contact Customer Service on 1800 654 767 Problem Cause The Appliance will not light at all Make sure you have new batteries installed in the correct position Negative should be down closest to you and Positive towards the back In high humidity conditions it may be necessary to clean and dry the battery box prior to operation Check for suffic...

Page 12: ...e from defects in workmanship and materials for the warranty period 2 Fitting and use Please ensure you a fit the Kingsley product in accordance with the product information and all relevant vehicle safety and compliance laws b use the Kingsley product for the purpose for which it was originally designed and in accordance with the product information and all relevant vehicle safety and compliance ...

Page 13: ...bushranger com au Free Call 1800 654 767 Australia only International 61 2 8700 0400 Fax 61 2 8700 0499 Email sales kingsleyenterprises com au Address 6A Brooks Road Ingleburn NSW 2565 ...

Reviews: