Gas system
7
Connect the external gas device to the connection point (Fig. 108,1).
Open the gas isolator tap (Fig. 108,2).
7.6
Crash protection unit switching facility (special
equipment)
The crash protection unit is an automatic switching facility with a control unit
for a two-bottle gas system. The switching facility automatically switches gas
supply from the primary bottle to the reserve bottle as soon as the primary
bottle is either empty or no longer ready for operation. The gas appliances may
still continue operation. The switching facility is suitable for all commercial gas
bottles from 3 kg to 33 kg. In the event of an accident or a too high angle of the
vehicle the gas supply will automatically be interrupted.
Construction of the unit
The crash protection unit consists of two flow restrictors with manual release
button (Fig. 109,6) a reversing valve (Fig. 109,4) with pressure regulator
(Fig. 109,2), an electrovalve (Fig. 109,5) and the operating unit with tricol-
oured LED. The reversing valve is installed between the two gas tubes
(Fig. 109,1).
Use the knob (Fig. 109,3) on the reversing valve to select which of the gas bot-
tles is to be used as a primary bottle and which is to be used as a reserve
bottle.
X
Do not use the switching facility in closed spaces.
Z
When the vehicle is equipped with the crash protection unit the living area
heater may be operated during the journey.
Z
If the vehicle is equipped with a panel of the DT series and the switching
facility is operated via this panel, the operating unit is redundant.
Z
Also read the manufacturer's instruction manual.
Fig. 109 Crash protection unit switching facility
Summary of Contents for A 650
Page 2: ...A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Instruction manual ...
Page 34: ...34 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Before the journey 3 ...
Page 52: ...52 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Pitching the motorhome 5 ...
Page 96: ...96 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Gas system 7 ...
Page 132: ...132 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Electrical system 8 ...
Page 164: ...164 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Appliances 9 ...
Page 184: ...184 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Sanitary fittings 10 ...
Page 196: ...196 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Care 11 ...
Page 210: ...210 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Maintenance 12 ...
Page 230: ...230 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Troubleshooting 14 ...
Page 234: ...234 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Special equipment 15 ...
Page 238: ...238 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Technical data 16 ...
Page 250: ...250 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Helpful notes 17 ...