222
A-Modell - 11/12 - Ausgabe 09/11 - 2096161 - BUE-0036-10EN
Troubleshooting
14
14.3
Fuel cell
14.4
Gas system
Z
Do not open the fuel cell. The fuel cell contains no parts that could be
repaired by itself.
Z
All faults are not displayed. If the faults cannot be rectified using the fol-
lowing table or the instruction manual for the fuel cell, please contact the
customer service.
Fault (display)
Cause
Remedy
Fuel cell cannot be
switched on
No battery connected,
battery connected incor-
rectly or totally dis-
charged
Inspect the connection
Fuse is defective
Replace fuse; if it hap-
pens again, contact the
customer service
Failure: Environment too
warm
Ambient temperature too
high (40 °C)
Fuel cell restarts when
the ambient temperature
is between 0 °C and
40 °C
X
In case of a defect of the gas system (gas odour, high gas consumption)
there is danger of explosion! Close regulator tap on the gas bottle imme-
diately. Open doors and windows and ventilate well.
X
If the gas system is defective: Do not smoke; do not ignite any open
flames, and do not operate electric switches (light switches etc.).
X
Have the defective gas system repaired by an authorised specialist
workshop.
Fault
Cause
Remedy
No gas
Gas bottle is empty
Change gas bottle
Gas isolator tap closed
Open the gas isolator tap
Regulator tap on the gas
bottle is closed
Open regulator tap on
the gas bottle
External temperature is
too low (-42 °C for pro-
pane gas, 0 °C for bu-
tane gas)
Wait for higher external
temperatures
Built-in appliance is de-
fective
Contact customer service
Summary of Contents for A 650
Page 2: ...A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Instruction manual ...
Page 34: ...34 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Before the journey 3 ...
Page 52: ...52 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Pitching the motorhome 5 ...
Page 96: ...96 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Gas system 7 ...
Page 132: ...132 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Electrical system 8 ...
Page 164: ...164 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Appliances 9 ...
Page 184: ...184 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Sanitary fittings 10 ...
Page 196: ...196 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Care 11 ...
Page 210: ...210 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Maintenance 12 ...
Page 230: ...230 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Troubleshooting 14 ...
Page 234: ...234 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Special equipment 15 ...
Page 238: ...238 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Technical data 16 ...
Page 250: ...250 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Helpful notes 17 ...