220
A-Modell - 11/12 - Ausgabe 09/11 - 2096161 - BUE-0036-10EN
Troubleshooting
14
No 230 V power supply
despite connection
230 V automatic circuit
breaker has triggered
Switch on the 230 V au-
tomatic circuit breaker
The mains connection is
de-energised
Check the mains connec-
tion
Starter or living area bat-
tery is not charged when
operated in 230 V mode
Jumbo flat fuse (50 A) on
the starter or living area
battery is defective
Replace jumbo flat fuse
(50 A) on the starter or
living area battery
Charger module in the
transformer/rectifier is
defective
Contact customer service
Living area battery is not
charged during vehicle
operation
Fuse on terminal D+ of
the alternator is defective
Replace fuse
Disconnector relay in the
transformer/rectifier is
defective
Contact customer service
12 V power supply does
not work
12 V power supply
switched off
Switch 12 V power sup-
ply on
Battery cut-off switch on
the transformer/rectifier
switched off or battery
separation activated
Switch on battery cut-off
switch or deactivate bat-
tery separation via the
panel
Living area battery is dis-
charged
Charging the living area
battery
Jumbo flat fuse (50 A) on
the living area battery is
defective
Replace jumbo flat fuse
(50 A) on the living area
battery
Disconnector relay in the
transformer/rectifier is
defective
Contact customer service
12 V power supply does
not work in 230 V opera-
tion
12 V power supply
switched off
Switch 12 V power sup-
ply on
Battery cut-off switch on
the transformer/rectifier
switched off or battery
separation activated
Switch on battery cut-off
switch or deactivate bat-
tery separation via the
panel
Charger module in the
transformer/rectifier is
defective
Contact customer service
230 V automatic circuit
breaker has triggered
Contact customer service
Jumbo flat fuse (50 A) on
the living area battery is
defective
Replace jumbo flat fuse
(50 A) on the living area
battery
Starter battery is dis-
charged in 12 V opera-
tion
Disconnector relay in the
transformer/rectifier is
defective
Contact customer service
Battery cut-off switch on
the transformer/rectifier
switched off or battery
separation activated
Switch on battery cut-off
switch or deactivate bat-
tery separation via the
panel
Fault
Cause
Remedy
Summary of Contents for A 650
Page 2: ...A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Instruction manual ...
Page 34: ...34 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Before the journey 3 ...
Page 52: ...52 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Pitching the motorhome 5 ...
Page 96: ...96 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Gas system 7 ...
Page 132: ...132 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Electrical system 8 ...
Page 164: ...164 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Appliances 9 ...
Page 184: ...184 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Sanitary fittings 10 ...
Page 196: ...196 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Care 11 ...
Page 210: ...210 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Maintenance 12 ...
Page 230: ...230 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Troubleshooting 14 ...
Page 234: ...234 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Special equipment 15 ...
Page 238: ...238 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Technical data 16 ...
Page 250: ...250 A Modell 11 12 Ausgabe 09 11 2096161 BUE 0036 10EN Helpful notes 17 ...