9
Key
No.
Description
Part No.
Quantity
IN3 IN4 IN5 IN6 IN7 IN8 IN9 IN10 IN11 IN12
5. Pilot Burner and Gas Valve, Intermittent Ignition (EI), Natural Gas
5A Pilot Burner, Honeywell Q348A1002
8236072
1
1
1
1
1
1
1
1
1
1
5B
Pilot Orifice, Honeywell 388146NE
Included
with 5A
1
1
1
1
1
1
1
1
1
1
5C Compression Nut/Fitting, 1/4" OD x 1/4
C.C. (Included with 5A and 5E)
8236109
2
2
2
2
2
2
2
2
2
2
5D
Pilot Tubing, 1/4" OD x 30"
8236122
1
1
1
1
1
---
---
---
---
---
Pilot Tubing, 1/4" OD x 40"
8236123
---
---
---
---
---
1
1
1
1
1
5E
Gas Valve, Honeywell VR8204C3007
81660145
1
1
1
1
---
---
---
---
---
---
Gas Valve, Honeywell VR8304P4306
81660161
---
---
---
---
1
1
1
1
1
2
5F
Igniter/Sensor Cable, 36", Honeywell
394800-36
8236084
1
1
1
1
1
1
1
1
1
1
5G Ground Wire Assembly
6136054
1
1
1
1
1
1
1
1
1
1
5. Pilot Burner and Gas Valve, Intermittent Ignition (EI), LP/Propane
5A Pilot Burner, Honeywell Q348A1010
8236081
1
1
1
1
1
1
1
---
---
---
5B
Pilot Orifice, Honeywell 388146KP
Included
with 5A
1
1
1
1
1
1
1
---
---
---
5C Compression Nut/Fitting, 1/4" OD x 1/4
C.C. (Included with 5A and 5E)
8236109
2
2
2
2
2
2
2
---
---
---
5D
Pilot Tubing, 1/4" OD x 30"
8236122
1
1
1
1
1
---
---
---
---
---
Pilot Tubing, 1/4" OD x 40"
8236123
---
---
---
---
---
1
1
---
---
---
5E
Gas Valve, Honeywell VR8204C3015
81660146
1
1
1
1
---
---
---
---
---
---
Gas Valve, Honeywell VR8304P4314
81660160
---
---
---
---
1
1
1
---
---
---
5F
Igniter/Sensor Cable, 36" Honeywell
394800-36
8236084
1
1
1
1
1
1
1
---
---
---
5G Ground Wire Assembly
6136054
1
1
1
1
1
1
1
---
---
---
Note: Gas Valve specifications shown for normal altitude (0-2000 feet). For High Altitude consult factory.
Summary of Contents for INDEPENDENCE IN10 CANADA
Page 4: ... Figure 1 Dimensional Drawing ...
Page 18: ...18 Figure 25 Recommended Water Piping for Circulator Zoned Heating System ...
Page 19: ...19 Figure 25A Recommended Water Piping for Zone Valve Zoned Heating System ...
Page 28: ...28 Figure 34 Vent Damper Schematic Wiring Diagram Figure 33 Vent Damper Harness to Limit ...
Page 29: ...29 THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 30: ...30 Figure 35 Wiring Diagrams Steam Continuous Ignition Standing Pilot Probe Low Water Cutoff ...
Page 32: ...32 Figure 36 Wiring Diagrams Steam Intermittent Ignition EI Probe Low Water Cutoff ...
Page 34: ...34 Figure 37 Wiring Diagrams Steam Continuous Ignition Standing Pilot Float Low Water Cutoff ...
Page 36: ...36 Figure 38 Wiring Diagrams Steam Intermittent Ignition EI Float Low Water Cutoff ...
Page 40: ...40 Figure 40 Wiring Diagrams Water Intermittent Ignition EI Intermittent Circulation ...
Page 42: ...42 Figure 41 Wiring Diagrams Water Continuous Ignition Standing Pilot Gravity Circulation ...
Page 44: ...44 Figure 42 Wiring Diagrams Water Intermittent Ignition EI Gravity Circulation ...
Page 46: ...46 Figure 43 Wiring Diagrams Water Continuous Ignition Standing Pilot Tankless Heater ...
Page 48: ...48 Figure 44 Wiring Diagrams Water Intermittent Ignition EI Tankless Heater ...
Page 51: ...51 Figure 48 Lighting Instructions Continuous Ignition System VR8200 and VR8300 Gas Valves ...
Page 52: ...52 Figure 49 Lighting Instructions Continuous Ignition System 7000 ERHC Gas Valve ...
Page 66: ...66 Honeywell Electronic Ignition Trouble Shooting Guide ...
Page 67: ...67 Honeywell Hot Surface to Pilot Trouble Shooting Guide ...
Page 80: ...80 ...
Page 84: ...84 ...
Page 87: ...87 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 88: ...88 ...