5
Key
No.
Description
Part No.
Quantity
IN3 IN4 IN5 IN6 IN7 IN8 IN9 IN10 IN11 IN12
4. Manifold and Main Burners (1 Inch Main Burners Only)
4A
Main Burner
8236099
2
4
6
8
11
13
15
17
20
22
4B
Main Burner with Pilot Bracket
(Continuous Ignition) (Q350 Pilot)
8236097
1
1
1
1
1
---
---
---
---
---
Main Burner with Pilot Bracket
(Continuous Ignition) (Q327 Pilot)
8236098
---
---
---
---
---
1
1
1
1
1
Main Burner with Pilot Bracket
(Intermittent Ignition) (Q348 Pilot)
8236098
1
1
1
1
1
1
1
1
1
1
4C
Manifold
82260033
1
---
---
---
---
---
---
---
---
---
82260043
---
1
---
---
---
---
---
---
---
---
82260053
---
---
1
---
---
---
---
---
---
---
82260063
---
---
---
1
---
---
---
---
---
---
82260073
---
---
---
---
1
---
---
---
---
---
82260083
---
---
---
---
---
1
---
---
---
---
82260093
---
---
---
---
---
---
1
---
---
---
82260103
---
---
---
---
---
---
---
1
---
---
82260113
---
---
---
---
---
---
---
---
1
---
82260123
---
---
---
---
---
---
---
---
---
1
4D
Natural
Gas
Only
Main Burner Orifice, #45 Pink
822711
3
5
7
9
---
---
---
---
---
---
Main Burner Orifice, #47 White
822710
---
---
---
---
12
14
16
18
21
23
4D
LP Only
Main burner Orifice, #55 Green
822708
3
---
---
---
---
---
---
---
---
---
Main Burner Orifice, 1.25 mm, Purple
822705
---
5
7
9
---
---
---
---
---
---
Main Burner Orifice, 3/64", Blue
822704
---
---
---
---
12
14
16
---
---
---
4E
Screw, Machine, Slotted Round Head,
10-32 x 3/16"
80860800
2
2
2
2
2
2
2
2
2
2
4F
Screw, Self Tapping, Phillips Pan
Head, 1/4 -20 x 1/2"
80860700
4
4
4
4
4
4
4
4
4
4
Note: Orifice Sizes shown for normal altitude (0-2000 feet). For High Altitude consult factory.
Summary of Contents for INDEPENDENCE IN10 CANADA
Page 4: ... Figure 1 Dimensional Drawing ...
Page 18: ...18 Figure 25 Recommended Water Piping for Circulator Zoned Heating System ...
Page 19: ...19 Figure 25A Recommended Water Piping for Zone Valve Zoned Heating System ...
Page 28: ...28 Figure 34 Vent Damper Schematic Wiring Diagram Figure 33 Vent Damper Harness to Limit ...
Page 29: ...29 THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 30: ...30 Figure 35 Wiring Diagrams Steam Continuous Ignition Standing Pilot Probe Low Water Cutoff ...
Page 32: ...32 Figure 36 Wiring Diagrams Steam Intermittent Ignition EI Probe Low Water Cutoff ...
Page 34: ...34 Figure 37 Wiring Diagrams Steam Continuous Ignition Standing Pilot Float Low Water Cutoff ...
Page 36: ...36 Figure 38 Wiring Diagrams Steam Intermittent Ignition EI Float Low Water Cutoff ...
Page 40: ...40 Figure 40 Wiring Diagrams Water Intermittent Ignition EI Intermittent Circulation ...
Page 42: ...42 Figure 41 Wiring Diagrams Water Continuous Ignition Standing Pilot Gravity Circulation ...
Page 44: ...44 Figure 42 Wiring Diagrams Water Intermittent Ignition EI Gravity Circulation ...
Page 46: ...46 Figure 43 Wiring Diagrams Water Continuous Ignition Standing Pilot Tankless Heater ...
Page 48: ...48 Figure 44 Wiring Diagrams Water Intermittent Ignition EI Tankless Heater ...
Page 51: ...51 Figure 48 Lighting Instructions Continuous Ignition System VR8200 and VR8300 Gas Valves ...
Page 52: ...52 Figure 49 Lighting Instructions Continuous Ignition System 7000 ERHC Gas Valve ...
Page 66: ...66 Honeywell Electronic Ignition Trouble Shooting Guide ...
Page 67: ...67 Honeywell Hot Surface to Pilot Trouble Shooting Guide ...
Page 80: ...80 ...
Page 84: ...84 ...
Page 87: ...87 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 88: ...88 ...