8
Key
No.
Description
Part No.
Quantity
IN3 IN4 IN5 IN6 IN7 IN8 IN9 IN10 IN11 IN12
5. Pilot Burner and Gas Valve, Continuous Ignition (Standing Pilot), Natural Gas
5A
Pilot Burner, Honeywell Q350A1321
8236065
1
1
1
1
1
---
---
---
---
---
Pilot Burner, Honeywell Q327A1006
8236022
---
---
---
---
1**
1
1
1
1
1
5B
Pilot Orifice, Honeywell 390686-22
Included
with 5A
1
1
1
1
1
---
---
---
---
---
Pilot Orifice, Honeywell 388146AG
---
---
---
---
---
1
1
1
1
1
5C Compression Nut/Fitting, 1/4" OD x 1/4
C.C. (Included with 5A)
8236109
2
2
2
2
2
2
2
2
2
2
5D
Pilot Tubing, 1/4" OD x 30"
8236122
1
1
1
1
1
---
---
---
---
---
Pilot Tubing, 1/4" OD x 40"
8236123
---
---
---
---
---
1
1
1
1
1
5E
Gas Valve, Honeywell VR8200C3005
81660143
1
1
1
1
---
---
---
---
---
---
Gas Valve, Honeywell VR8200C6065
100333-01
1**
1**
1**
1**
---
---
---
---
---
---
Gas Valve, Honeywell VR8300C4027
81660154
---
---
---
---
1
1
1
---
---
---
Gas Valve, Honeywell VR8300C4266
100334-01
---
---
---
---
1**
1**
1**
---
---
---
Gas Valve, Robertshaw
7000ERHC-S7C
81660156
---
---
---
---
---
---
---
1
1
1
Gas Valve, ITT K3A451
81660080
---
---
---
---
---
---
---
1
1
1
5F
Thermocouple, Honeywell Q309A
8236024
1
1
1
1
1
1
1
1
1
1
5. Pilot Burner and Gas Valve, Continuous Ignition (Standing Pilot), LP/Propane
5A
Pilot Burner, Honeywell Q350A1339
8236066
1
1
1
1
1
---
---
---
---
---
Pilot Burner, Honeywell Q327A1147
8236023
1**
1**
1**
1**
1**
1
1
---
---
---
5B
Pilot Orifice, Honeywell 390686-23
Included
with 5A
1
1
1
1
1
---
---
---
---
---
Pilot Orifice, Honeywell 388146KR
---
---
---
---
---
1
1
---
---
---
5C Compression Nut/Fitting, 1/4" OD x 1/4
C.C. (Included with 5A and 5E)
8236109
2
2
2
2
2
2
2
---
---
---
5D
Pilot Tubing, 1/4" OD x 30"
8236122
1
1
1
1
1
---
---
---
---
---
Pilot Tubing, 1/4" OD x 40"
8236123
---
---
---
---
---
1
1
---
---
---
5E
Gas Valve, Honeywell VR8200C3013
81660144
1
1
1
1
---
---
---
---
---
---
Gas Valve, Honeywell VR8300C4035
81660163
---
---
---
---
1
1
1
---
---
---
5F
Thermocouple, Honeywell Q309A
8236024
1
1
1
1
1
1
1
---
---
---
Note: Gas Valve specifications shown for normal altitude (0-2000 feet). For High Altitude consult factory.
** 40mm Burners Only
Summary of Contents for INDEPENDENCE IN10 CANADA
Page 4: ... Figure 1 Dimensional Drawing ...
Page 18: ...18 Figure 25 Recommended Water Piping for Circulator Zoned Heating System ...
Page 19: ...19 Figure 25A Recommended Water Piping for Zone Valve Zoned Heating System ...
Page 28: ...28 Figure 34 Vent Damper Schematic Wiring Diagram Figure 33 Vent Damper Harness to Limit ...
Page 29: ...29 THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 30: ...30 Figure 35 Wiring Diagrams Steam Continuous Ignition Standing Pilot Probe Low Water Cutoff ...
Page 32: ...32 Figure 36 Wiring Diagrams Steam Intermittent Ignition EI Probe Low Water Cutoff ...
Page 34: ...34 Figure 37 Wiring Diagrams Steam Continuous Ignition Standing Pilot Float Low Water Cutoff ...
Page 36: ...36 Figure 38 Wiring Diagrams Steam Intermittent Ignition EI Float Low Water Cutoff ...
Page 40: ...40 Figure 40 Wiring Diagrams Water Intermittent Ignition EI Intermittent Circulation ...
Page 42: ...42 Figure 41 Wiring Diagrams Water Continuous Ignition Standing Pilot Gravity Circulation ...
Page 44: ...44 Figure 42 Wiring Diagrams Water Intermittent Ignition EI Gravity Circulation ...
Page 46: ...46 Figure 43 Wiring Diagrams Water Continuous Ignition Standing Pilot Tankless Heater ...
Page 48: ...48 Figure 44 Wiring Diagrams Water Intermittent Ignition EI Tankless Heater ...
Page 51: ...51 Figure 48 Lighting Instructions Continuous Ignition System VR8200 and VR8300 Gas Valves ...
Page 52: ...52 Figure 49 Lighting Instructions Continuous Ignition System 7000 ERHC Gas Valve ...
Page 66: ...66 Honeywell Electronic Ignition Trouble Shooting Guide ...
Page 67: ...67 Honeywell Hot Surface to Pilot Trouble Shooting Guide ...
Page 80: ...80 ...
Page 84: ...84 ...
Page 87: ...87 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 88: ...88 ...