Troubleshooting
107
TYER WILL NOT POWER UP
No Error Code is Displayed
SAFETY WARNING
The following troubleshooting procedure may require that tests be made
with the electrical enclosures open and power turned ON. These tests
should only be conducted by authorized personnel who are aware of the
electrical and mechanical hazards present.
Turn the disconnect switch to ON with STOP
switch pulled out. The fault light should come on
and you should hear the alarm horn. Does this
work properly?
Continued on next page.
Is 48 VDC present at J4
connector on the main
board?
Is 48 VDC present At PSM1
OUTPUT?
Troubleshoot where main
board power is being lost.
Possible causes (wiring,
STOP Switch(s), CB4 and
CB2)
Is AC line voltage
present at PSM1
INPUT?
Power supply
bad.
Troubleshoot
where line voltage
Is being lost.
Possible causes
(wiring, FLTR1,
CB1 and service
to DISC)
Does 7-seg LED display
startup sequence?
Most likely bad main board.
If changing board does not
remedy problem, then
troubleshoot I/O (P1
through P6).
Check all cable
connections. Are 24V, 12V,
5V LED’s on?
Most likely bad
CPU.
Most likely bad main
board. If changing
board does not
remedy problem, then
troubleshoot I/O (P1
through P6).
Flow Chart 0-1 Tyer Will Not Power Up
Summary of Contents for 2200M
Page 10: ......
Page 11: ...Chapter 1 Introduction...
Page 18: ......
Page 19: ...Chapter 2 Key Components...
Page 41: ...Chapter 3 Installation...
Page 42: ......
Page 50: ......
Page 51: ...Chapter 4 Operation...
Page 52: ......
Page 64: ......
Page 65: ...Chapter 5 Settings and Adjustments...
Page 66: ......
Page 84: ......
Page 85: ...Chapter 6 Communications...
Page 86: ......
Page 103: ...Chapter 7 Troubleshooting...
Page 104: ......
Page 122: ...118 Chapter 7 Flow Chart 0 12 Error Code E115 and E116...
Page 123: ...Troubleshooting 119 Flow Chart 0 13 Error Code E115 and E116 cont d...
Page 124: ...120 Chapter 7 Flow Chart 0 14 Error Code E117...
Page 126: ...122 Chapter 7 Flow Chart 0 16 Error Code E122 or E123...
Page 127: ...Troubleshooting 123 Flow Chart 0 17 Error Code E124...
Page 128: ...124 Chapter 7 Flow Chart 0 18 Error Code E125 and E126...
Page 129: ...Troubleshooting 125 Flow Chart 0 19 Error Code E125 and E126 cont d...
Page 130: ...126 Chapter 7 Flow Chart 0 20 Error Code E127...
Page 131: ...Troubleshooting 127 Flow Chart 0 21 Error Code E131...
Page 132: ...128 Chapter 7 Flow Chart 0 22 Error Code E132 or E133...
Page 133: ...Troubleshooting 129 Flow Chart 0 23 Error Code E134...
Page 134: ...130 Chapter 7 Flow Chart 0 24 Error Code E135 and E136...
Page 135: ...Troubleshooting 131 Flow Chart 0 25 Error Code E135 and E136 cont d...
Page 136: ...132 Chapter 7 Flow Chart 0 26 Error Code E137...
Page 138: ...134 Chapter 7 Flow Chart 0 28 Error Code E146 cont d...
Page 144: ......
Page 145: ...Chapter 8 Maintenance...
Page 146: ......
Page 154: ......
Page 155: ...Chapter 9 Test Procedures...
Page 156: ......
Page 164: ......
Page 165: ...Chapter 10 Parts and Drawings...
Page 166: ......
Page 173: ...Right Hand Shown...
Page 179: ...Front Upper Plate 2200M 211102 04 REV D Right Hand Shown...
Page 183: ...Electrical Components 2200M 211102 06 REV C See Pg 16 See Pg 16 Right Hand Shown...
Page 185: ...Infeed Belt Components 211106 Rev B Right Hand Shown...
Page 187: ...Connector Plate 210625 Rev B Board Mount Assembly 210616 Rev B RH Not Shown Right Hand Shown...
Page 189: ......
Page 191: ......
Page 193: ...Right Hand Shown...
Page 195: ...Right Hand Shown...
Page 199: ...Tapered Brush Air Regulator Drawing 211173 Rev A...
Page 201: ......
Page 203: ......
Page 205: ......
Page 207: ......
Page 209: ...Install Kit Drawing 103531 200...
Page 210: ...FOLD OUT TO VIEW DRAWING Electrical Schematics 40 39 Install Kit Drawing 103531 200...
Page 211: ...EDO651 J ladder...
Page 212: ...FOLD OUT TO VIEW DRAWING EDO651 J ladder EDO651 J Wire Diagram 42 41...
Page 213: ......
Page 214: ...FOLD OUT TO VIEW DRAWING EDO651 J Layout EDO651 J Wire Diagram 43 44...