User Guide
131
www.bull.com
SYSCFG
The
SYSCFG
command-line utility is used to configure the IP address and user
credentials of the BMC. Although Windows and Linux versions of this utility are
provided, their command syntax is the same.
Refer to the
System Configuration Utility User Guide
found on the ExpressBuilder
DVD for further details of each command.
Execute the following commands (in bold) to change the required parameters.
Note:
■
These commands must be run from the directory containing
the SYSCFG.EXE program.
■
Entering some commands may produce an error, caused by
the BMC being too busy at that time to respond. Re-enter
the command a few seconds later.
Reset BMC
Restore the factory default BMC settings:
Command:
syscfg /rfs
Reset the BMC:
Command:
syscfg /rbmc
Note:
Wait 10 seconds before entering further
configuration commands.
IP address Configuration
Note: The IP address of the BMC operates independently
of any operating system IP address and must be unique to
avoid conflicts.