1.
Replace a hard disk drive and power on the server.
2.
Run the LSI Logic Software RAID Setup Utility.
3.
Select
Rebuild
from the
Top
menu.
The
Rebuild – Physical Drives Selection Menu
screen appears.
Figure 41: Rebuild – Physical Drives Selection Menu
4.
Move the cursor onto the hard disk drive displaying "FAIL" and then press
Space
to select it.
Several hard disk drives can be selected (simultaneous rebuilding.)
5.
The
Fail
indication for the selected hard disk drive starts blinking.
6.
Once the hard disk drive is selected, press
F10
to start rebuilding.
7.
Press
Yes
when prompted to do so. The rebuild process starts.
When the progress bar in the
Rebuild Physical Drives in Progress
screen
reaches 100%, the rebuilding is completed.
8.
Press
Esc
to return to the
Top
menu and exit the LSI Logic Software RAID
Setup Utility.