Removing the disk drive
1.
From the IBM Power RAID Configuration Utility display, select
Work with disk unit recovery
. Press
Enter.
2.
From the Work with Disk Unit Recovery display, select
Concurrent remove device
. Press Enter. A
Concurrent Device Remove display is shown, similar to the following display.
3.
Type option
1
(Select) next to the location for the disk drive you want to replace. Press Enter.
4.
The Verify Device Concurrent Remove display is shown. The concurrent maintenance light turns on
for that disk drive slot.
5.
On the Verify Device Concurrent Remove display, verify that the selected disk drive is the disk drive
you want to replace, then press Enter. The identify light turns on for the disk drive.
Attention:
To prevent loss of data, ensure that the disk drive is not in use.
6.
The Complete Device Concurrent Remove display is shown.
Concurrent Device Remove
Choose a single location for remove operations
1=Select
OPT Name
PCI/SCSI Location
Description
Status
--- ------ -------------------------- ------------------------- -----------------
sdc
0000:41:01.0.1/0:8:0
Physical Disk
Active
0000:41:01.0.1/0:5:
Empty
sdb
0000:41:01.0.1/0:4:0
Physical Disk
Active
sda
0000:41:01.0.1/0:3:0
Physical Disk
Active
0000:41:01.0.1/1:8:
Empty
sdf
0000:41:01.0.1/1:5:0
Physical Disk
Active
sde
0000:41:01.0.1/1:4:0
Physical Disk
Active
sdd
0000:41:01.0.1/1:3:0
Physical Disk
Active
0001:61:01.0.2/0:8:
Empty
sdh
0001:61:01.0.2/0:9:0
Physical Disk
Active
sdg
0001:61:01.0.2/0:3:0
Physical Disk
Active
Figure 4. Example Concurrent Device Remove display
Chapter 1. Removing and replacing FRUs
33