14.
Stop removing the cache battery pack
The flashing LED indicates that there is
cached data on the battery that has not been
saved. This data will be lost if the battery is
removed at this time. Please complete this
service procedure without replacing the
battery, then retry it to ensure all cache data is
saved before the battery is replaced.
Go to step 17 on page 21.
15.
Remove the cache battery pack
1.
Move the cache battery lever
(A)
away
from the connector to disengage the
battery from the connector.
2.
Slide the cache battery pack
(B)
out of the
mounting guides and remove it from the
controller.
3.
Attention:
Do not remove battery if LED
(C)
is flashing; cache data exists.
20
Power Systems: IBM Power 550 Express (8204-E8A and 9409-M50) removal and replacement procedures