System Overview 1-3
Chassis Feature Summary
Table 1-2 contains a summary of the chassis features.
Table 1-2. Chassis Feature Summary
Feature
Comment
Power system with redundancy
The 750 watt, autoranging power supplies include integrated fans for
cooling. These power supplies operate at 100–120VAC or
200–240 VAC. When the server is configured with three supplies
(2 + 1), the third provides redundancy. The supplies can be replaced—
hot-swapped—without turning off server power. The server requires a
minimum of two power supplies. LEDs on the back of the power supply
indicate power on, failure, and predictive failure.
Server chassis
The electrogalvanized metal used in manufacturing the server chassis
minimizes electromagnetic interference (EMI) and radio frequency
interference (RFI).
The peripheral bay provides the interface for 3.5- and 5.25-inch media.
It can support:
•
One 5.25-inch IDE CD-ROM drive in the 5.25-inch half-height bay.
(Optional: any IDE or single-ended SCSI device, like a tape drive.)
•
Two 3.5-inch wide by 1.0- or 1.6-inch hot-swappable low-voltage
differential SCSI (LVDS) hard disk drives mounted side-by-side in
the 3.5-inch hot-swapping bays. These bays allow hot-swapping of
hard disk drives without shutting down the server.
Ten hot-plug PCI I/O expansion slots.
The plastic front bezel provides airflow and easy access to drives in the
hot-swapping bays. The removable top covers provide proper airflow
and easy access to components inside the server. Only technically
qualified personnel should remove the server covers.
Cooling system with redundancy
Six fans (5 + 1) cool and circulate air through the server. The sixth fan
is redundant. The fans can be replaced—hot-swapped—without
turning off server power. An LED indicator mounted next to each fan
guarantees positive identification of the failed fan.
Integrated power supply fans—two or three—cool and circulate air
through the power supplies and the bottom of the chassis.
Server management
Interintegrated circuit bus (I
2
C) for diagnostic and intrachassis
communication. Interchassis management bus (ICMB) for interchassis
platform management communications.
Real-time clock/calendar (RTC).
Front panel controls and indicators (LEDs).
Basic Input/Output System (BIOS), Power-on Self Test (POST), and
Setup Utility stored in a flash memory device.
System Setup Utility (SSU).
Symbios
SCSI Utility.
Emergency Management Port (EMP) utility.
Field Replacement Unit (FRU) and Sensor Data Record (SDR) load
utility.
Summary of Contents for DPS7000/XTANOVASCALE 7000 180Rb 7
Page 2: ......
Page 11: ...Contents ix Glossary Equipment Log Index ...
Page 12: ...x Contents ...
Page 60: ...2 24 Setting Up the System ...
Page 111: ......
Page 155: ...Disassembly and Reassembly 4 45 OM07508 Figure 4 32 Peripheral Bay ...
Page 173: ...Disassembly and Reassembly 4 63 Figure 4 45 ICMB Board ...
Page 208: ...5 20 Problem Solving ...
Page 209: ...6 Illustrated Parts Breakdown Exploded View Field Replaceable Units ...
Page 227: ...B Connectors Overview External Device Connector Pin Information ...
Page 244: ...10 Glossary ...
Page 248: ...4 Equipment Log ...
Page 254: ...Index 6 ...
Page 257: ......
Page 258: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE 99 A9 96US 00 REFERENCE ...