SCS 104
CAUTION
Supply cable
The power adapter must be suitable for the maximum power input of the device. It must
be heat-resistant and must not come into contact with hot surfaces. The power adapter
must meet IEC60227 or IEC60245. Or be approved by another recognised testing body.
Run the lines so the insulation will not be damaged. If necessary, secure the lines with suitable means and avoid excess line
lengths.
The power and voltage supply must be equipped with ELCB.
The ELCB (tripping current 30 mA) must shut off the load within the specified period (200 ms at 115 VAC, 40 ms at 230 VAC). It
must be suitable for the maximum load.