80
Amber
If there is a status message, the power LED will blink amber. The pattern of the blink gives the information code. You
can also see any status messages in NAS Navigator2.
Place
Status
10s Place
The LED flashes for 1.0 seconds every 0.3 seconds. This gives the tens place
of the information code.
1s Place
The LED flashes for 0.5 seconds every 0.3 seconds. This gives the ones place
of the information code.
Information Code
Description
Corrective Action
I10
System temperature is too high.
Move the LinkStation to a cool location.
Do not place objects in the area around
the LinkStation.
I11
Drive x has too many bad sectors.
Replace hard drive x.
I12
Operating in degraded mode.
-
I13
Formatting RAID array x.
-
I14
Checking RAID array x.
-
I15
Examining the error status of RAID array
x.
Note:
Transfer speeds are slower during
the examination process.
-
I16
Creating RAID array x.
-
I17
Resynchronizing RAID array x.
Note:
Transfer speeds are slower during
resynchronization.
-
I18
Rebuilding RAID array x.
Note:
Transfer speeds are slower during
the rebuilding process.
-
I19
Writing 0s to RAID array x, erasing all
data.
-
I20
Formatting hard drive x.
-
I21
Checking hard drive x.
-
I22
Erasing the data for hard drive x.
-
I23
System is being initialized.
-
I25
Updating the LinkStation firmware.
-
I26
Initializing all settings.
Don't turn off the LinkStation.
I27
Checking USB hard drive.
-
I28
Formatting USB hard drive.
Don't turn off the LinkStation.
I46
Data migration or conversion (RAID
migration) is in progress.
Don't turn off the LinkStation.
I47
Data migration or conversion (RAID
migration) is in progress.
Don't turn off the LinkStation.
I52
A new firmware version has been
released.
Update the firmware.
I54
A backup job has failed.
Make sure that the backup job is
configured correctly. Make sure that the
NAS is on and not in standby mode. If
the backup job still fails, check the status
of the network and backup source and
destination.