4
Installation
Logano GE615 - We reserve the right to make any changes due to technical modifications.
14
z
Clean nipple with a rag soaked in white spirit and coat
evenly with red lead putty.
z
Insert nipple directly into the upper (size 4, 181/70)
and lower (size 2, 119/50) hub on the rear section.
z
Rubber hammer nipple home with alternate heavy
blows.
z
Use a file to remove any burrs.
Fig 10 Driving nipples home
z
Coat the packing grooves with adhesive (adhesive
base)
Fig 11 Coating the packing grooves with adhesive
1
Packing grooves
The upper nipple must protrude
approx. 43 mm and the lower nipple
approx. 32 mm out of the corresponding
hubs.
The packing grooves must be clean and dry
to enable the packing cord to adhere
properly.
Caution: Risk to health
through noxious vapours and skin contact
during the processing of materials such as
adhesives, adhesive bases or red lead putty.
z
Observe processing and safety
instructions on the material packaging.
z
Ensure good ventilation in the installation
area.
z
wear work gloves to avoid skin contact.
z
The product and its container must be
treated as hazardous waste for disposal
purposes.
Summary of Contents for Logano GE615