Page 24
SECTION V
PRE-FAB INSERT INSTALLATION
INSTALLATION PRECAUTIONS
This room heater is listed by Warnock-Hersey Laboratories for installation into the following Zero-Clearance
Cabinet Models. These are:
MAJESTIC
—
M-36, M-43, L-36, L-42, MD36, MD42, MD36-AO, MD42-AO
HEATILATOR
—
FP36, 3036, 3042, 3048, 3138, 3138 EP
PREWAY
—
DW36, DW42, BI36, BI42, BI36B, BI42B, BI36EM, BI42EM, BI36CEM, BR42CEM,
BI36SEM, BI42SEM
NOTE: A preway unit has to use insert trim panels.
Other models of those brands may also be acceptable for installation of the Model 20 unit into them. However,
factory approval from New Buck Corporation and Warnock-Hersey Laboratories is required prior to installation.
Installation must conform to New Buck Corporation installation instructions or addendums.
INSTALLATION
(Pre-Fab Fireplace Insert)
MINIMUM CLEARANCES
INSTALLATION PREPARATION
Pre-Fab Fireplace
1. Relocate furniture and other materials away from front of fireplace to allow free access to fireplace.
2. Cover hearth and adjacent floor areas with drop cloth to protect from soiling or marring surface.
3. Remove existing fireplace damper plate/damper rod assembly.
FIGURE 1 PRE-FAB FIREPLACE INSERT
Summary of Contents for MODEL 20