Page 27
2. To complete this installation, follow the basic masonry fireplace trim kit installation instructions
except:
The trim kit may have to be cut down in size so as not to block any cooling vents/chambers of the Pre-
Fab Fireplace.
3. To complete methods 1 and 2:
Position heater into the Pre-Fab Fireplace and center flue exit under connector.
4. Slide connector (or slip connector) down into flue exit of heater approximately 3/8”, check that damper
operates without hitting connector. Now, seal connector to heater (and fireplace throat if method #1 is
used) using refractory cement.
CAUTION! Do not loosen ceramic blanket.
5. CAUTION! Crimped end of connector must be placed into heater throat.
6. Check installation minimum clearances and install an approved heater extension or floor protector to
meet at least the minimum clearances.
This heater is now ready for use. Please read heater operation Section VII of this manual before burning a fire in the
heater.