Page 3 of 40
Installation, Maintenance and Operation Manual V24a (June 2012)
British Telecommunications plc 2012
PRODUCT
SECURE 2
SECURE 3
SECURE IP
Both paths working, PSTN/IP path fails – fault reported in
2 MINS
2 MINS
3 MINS
Both paths working, Radio path fails – fault reported in
5-55 MINS
5-55 MINS
3-13 MINS
Only Radio path working and it fails – fault reported in
55 MINS
55 MINS
3-6 MINS
Only PSTN/IP path working and it fails – fault reported in
25 HOURS
5 HOURS
3 MINS
If both paths failed simultaneously – fault reported in
55 MINS
55 MINS
6 MINS
Primary Polling Frequency
5 MINS
5 MINS
30 SECS
EN GRADE
2
3
4
ATS VALUE PRIMARY
ATS4
ATS4
ATS5
ATS VALUE SECONDARY
ATS3
ATS4
ATS4
Figure 2 - Polling rates and communication fail alarm transmission times
Note: The polling rates and communication fail alarm transmission times in Fig 2 may be liable to
change. For the latest information, refer to the Technical information sheet at
http://www.redcare.bt.com
Note: Where the Redcare Secure unit is connected to a PSTN line (Secure 2 & 3) then the line
should be either a dedicated line, or a line of low usage, to ensure that the necessary outgoing test
calls and alarm calls can be made when required.