![BT Redcare Secure 2 Installation, Maintenance And Operation Manual Download Page 20](http://html.mh-extra.com/html/bt/redcare-secure-2/redcare-secure-2_installation-maintenance-and-operation-manual_2824512020.webp)
Page 19 of 40
Installation, Maintenance and Operation Manual V24a (June 2012)
British Telecommunications plc 2012
Line voltage alarm
delay
. Time to signal a PSTN Voltage Failure alarm (pin 955). Default 120
seconds. (Secure 2&3 only). Also applies to GPOP1
Line voltage restore
delay
. Time to signal a PSTN Voltage Failure restore (pin 955). Default 30
seconds. (Secure 2&3 only). Also applies to GPOP1
Line in use (LIU) Indicator
. Enable / Disable the PSTN voice detection circuitry within the unit’s
PSTN modem (Secure 2&3 only – LIU is used to detect when the PSTN line is in use by another
telephone. If Line Voltage monitoring is enabled this setting is ignored)
Output Settings
including the definition of the operation and polarity of the General Purpose
Outputs (1-3). (Default BSIA form 175 mode)
Line Fault Debounce time (Mins).
Set the delay before GPOP1 state changes. t1,t2,t3,t4,t5,t6.
Where t1=IP fail delay, t2=IP restore delay, t3=GPRS fail delay, t4=GPRS restore delay, t5=PSTN
dial fail delay, t6=PSTN dial restore delay. Default 2,0,15,0,15,0 (S/W Version >52 only)
Account Nbr / TA ID
This number can be used to identify the site. (optional)
IP Settings
including DHCP Client or static local IP and gateway addresses (Secure IP only).
On completion of the configuration, click the “
Save/Reboot
” button at the bottom of the screen and
remove the header from J903. Wait 1 minute for the save re-boot process to complete.