III - 65
(2) Turn the upper cover upside down.
(3) Bend the FFC of the tape sensor PCB ASSY as shown in the figure below, and
secure it with the filament tape so that do not contact the section "A" and "B" of
the upper cover.
Figure 3.5-41 Attaching the Filament Tape
(4) Pass the FFC of the tape sensor PCB ASSY through the hole of the machine.
Assemble the upper cover onto the machine and secure it with the five screws.
Figure 3.5-42 Installing the Upper Cover
Upper cover
"A"
"B"
Filament tape
FFC
Taptite, bind B M2.6 x 8
Upper cover
Hole
Screw, bind M2.6 x 4
FFC