![Brother MFC-J6510DW Service Manual Download Page 376](http://html.mh-extra.com/html/brother/mfc-j6510dw/mfc-j6510dw_service-manual_54363376.webp)
5-72
Confidential
AMS03
(Maintenance assurance 1)
• Selector 1: Protection of head caps from drying
If the protection function is enabled with this selector, the head/carriage unit automatically
returns to the home position (head capping position) for flushing each time the machine
prints the specified number of pages in order to protect the inside of the head caps from
drying up. This function is useful in a dry environment or for heavy duty print per printing
cycle.
• Selectors 2 and 3: Auto capping start time
If data transfer from the PC stops midway through printing for some reason in the PC, the
head/carriage unit automatically returns to the home position (head capping position) after
the specified auto capping start time (default: 30 seconds) to prevent the head surface from
drying up. At the restart of printing after the auto capping operation, print image
unevenness could occur. To avoid it, increase the auto capping start time with these
selectors.
• Selector 4: Purge more powerful than normal purge
Setting this selector to "1" automatically selects a purge more powerful than the normal
purge from the first if the purge is initiated immediately after printing.
• Selectors 7 and 8: Automatic purging interval programmed for matching the ambient
temperature
The "automatic purging interval programmed for matching the ambient temperature" is
enabled by default. If the machine is set in an excessively hot or cold place, therefore, the
automatic purging interval becomes short, resulting in increased ink waste.
Disabling this interval enables the one programmed for the ordinary temperature. In the
first printing after a long no-print period, however, the print quality may lower.
Selector
No.
Function
Setting and Specifications
1
Protection of head caps from drying
0: Disable (default)
1: Enable
2
3
Auto capping start time
No. 2
3
0
0
: 30 seconds (default)
0
1
: 5 seconds
1
0
: 15 seconds
1
1
: 300 seconds
4
Purge more powerful than normal
purge
0: Disable (default)
1: Enable
5
6
Not used.
7
Automatic purging interval
programmed for matching the
ambient temperature (for color ink)
0: Enable (default)
1: Disable
8
Automatic purging interval
programmed for matching the
ambient temperature (for black ink)
0: Enable (default)
1: Disable
Summary of Contents for MFC-J6510DW
Page 15: ...xii Confidential ...
Page 16: ...xiii Confidential ...
Page 17: ...xiv Confidential ...
Page 18: ...xv Confidential ...
Page 19: ...xvi Confidential ...
Page 128: ...3 3 Confidential 3 2 PACKING For models with paper tray 2 ...
Page 273: ...4 13 Confidential EXIT Adjust Check Pattern 1 ...
Page 274: ...4 14 Confidential EXIT Adjust Check Pattern 2 ...
Page 275: ...4 15 Confidential EXIT Adjust Check Pattern 3 ...
Page 276: ...4 16 Confidential KEISEN2 LF300 EXIT ADJUST PATTERN ...
Page 278: ...4 18 Confidential KEISEN GAP EXIT ADJUST PATTERN Line 1 Line 2 Line 3 ...
Page 280: ...4 20 Confidential Vertical Alignment Check Patterns ...
Page 283: ...4 23 Confidential Left Right and Bottom Margin Check Pattern ...
Page 286: ...4 26 Confidential Print Pattern for Creating Head Calibration Data ...
Page 302: ...4 42 Confidential ADF Copy Chart C A B D ...
Page 312: ...5 8 Confidential Print Pattern for Creating Head Calibration Data ...
Page 314: ...5 10 Confidential Scanning Compensation Data List ...
Page 317: ...5 13 Confidential Nozzle Test Pattern ...
Page 320: ...5 16 Confidential Configuration List ...
Page 337: ...5 33 Confidential EXIT Adjust Check Pattern 1 ...
Page 338: ...5 34 Confidential EXIT Adjust Check Pattern 2 ...
Page 339: ...5 35 Confidential EXIT Adjust Check Pattern 3 ...
Page 340: ...5 36 Confidential KEISEN2 LF300 EXIT ADJUST PATTERN ...
Page 346: ...5 42 Confidential Vertical Alignment Check Pattern ...
Page 349: ...5 45 Confidential Left Right and Bottom Margin Check Pattern ...
Page 383: ...6 4 Confidential Power supply PCB 100 V series ...
Page 384: ...6 5 Confidential Power supply PCB 200 V series ...
Page 385: ...6 6 Confidential Wiring diagrams ...