![Brother MFC-J6510DW Service Manual Download Page 161](http://html.mh-extra.com/html/brother/mfc-j6510dw/mfc-j6510dw_service-manual_54363161.webp)
3-36
Confidential
[ 3 ] Disconnecting Cables and Removing Accessories
(1) Disconnect the following:
- Power cord from the electrical outlet (or from the machine in the case of 200 V models)
- Modular jack of the telephone line
- USB cable, if connected
- LAN cable, if connected (if not connected, remove the LAN cap)
- USB digital camera cable or USB flash memory drive, if connected
- Modular jack of the external telephone set from the external telephone line jack, if
connected (if not connected, remove the EXT cap)
(2) Remove the paper tray ASSY #1 (and ASSY #2).
(3) Remove memory cards if inserted in the machine.
(4) Open the ink cartridge cover, remove all four ink cartridges, and set the protective part
instead. Check that the right-hand latch fits in the hole provided in the ink refill ASSY.
Telephone line cord
(3_001)
EXT cap
Paper tray ASSY #1
Paper tray ASSY #2
Protective
cap
Power cord
200 V series
LAN
USB
Protective part
(3_002)
Summary of Contents for MFC-J6510DW
Page 15: ...xii Confidential ...
Page 16: ...xiii Confidential ...
Page 17: ...xiv Confidential ...
Page 18: ...xv Confidential ...
Page 19: ...xvi Confidential ...
Page 128: ...3 3 Confidential 3 2 PACKING For models with paper tray 2 ...
Page 273: ...4 13 Confidential EXIT Adjust Check Pattern 1 ...
Page 274: ...4 14 Confidential EXIT Adjust Check Pattern 2 ...
Page 275: ...4 15 Confidential EXIT Adjust Check Pattern 3 ...
Page 276: ...4 16 Confidential KEISEN2 LF300 EXIT ADJUST PATTERN ...
Page 278: ...4 18 Confidential KEISEN GAP EXIT ADJUST PATTERN Line 1 Line 2 Line 3 ...
Page 280: ...4 20 Confidential Vertical Alignment Check Patterns ...
Page 283: ...4 23 Confidential Left Right and Bottom Margin Check Pattern ...
Page 286: ...4 26 Confidential Print Pattern for Creating Head Calibration Data ...
Page 302: ...4 42 Confidential ADF Copy Chart C A B D ...
Page 312: ...5 8 Confidential Print Pattern for Creating Head Calibration Data ...
Page 314: ...5 10 Confidential Scanning Compensation Data List ...
Page 317: ...5 13 Confidential Nozzle Test Pattern ...
Page 320: ...5 16 Confidential Configuration List ...
Page 337: ...5 33 Confidential EXIT Adjust Check Pattern 1 ...
Page 338: ...5 34 Confidential EXIT Adjust Check Pattern 2 ...
Page 339: ...5 35 Confidential EXIT Adjust Check Pattern 3 ...
Page 340: ...5 36 Confidential KEISEN2 LF300 EXIT ADJUST PATTERN ...
Page 346: ...5 42 Confidential Vertical Alignment Check Pattern ...
Page 349: ...5 45 Confidential Left Right and Bottom Margin Check Pattern ...
Page 383: ...6 4 Confidential Power supply PCB 100 V series ...
Page 384: ...6 5 Confidential Power supply PCB 200 V series ...
Page 385: ...6 6 Confidential Wiring diagrams ...