5-72
Confidential
2.3
Counter Reset of Consumable Parts
(Drum unit/Belt unit)
<Function>
After replacing a drum unit or belt unit, perform this function to increase the replacement count
by one and reset the count to clear the “Replace ***” warning.
<Operating procedure>
(1) Press the
(
Settings) key in the ready state.
(2) Press the
All Settings
key.
(3) Press the
or
key to display “Machine Info.” and then press the
Machine Info.
key.
(4) Press the
or
key to display “Parts Life” and then press the
Parts Life
key.
(5) Hold down the
#
key for 5 seconds or more. “Reset Menu” is displayed on the LCD.
(6) “Drum” and “Belt Unit” are displayed on the LCD. Press the key of the part you want to
reset. “Reset *****?” is displayed on the LCD. (******* represents the selected part name.)
(7) Press the
Yes
key. “Accepted” is displayed on the LCD and the counter of the selected
part is reset.
The consumable parts that can be selected are shown in the table below.
LCD
Part name
Drum
Drum unit
Belt Unit
Belt unit