3-155
Confidential
9.55 Paper Eject ASSY
(1) Disconnect the two Connectors (CN1 and CN2) from the High-voltage power supply PCB
ASSY.
(2) Release the wiring of the High-voltage main harness ASSY.
Fig. 3-216
(3) Remove the four Taptite bind B M4x12 screws and remove the Paper eject ASSY from
the Main body.
Fig. 3-217
Harness routing: Refer to
CN1
CN2
High-voltage power supply PCB ASSY
<Right side>
Paper eject ASSY
Taptite bind B M4x12
Paper eject ASSY
Main body
Taptite bind B M4x12
<Back side>