2-134
Confidential
4.14.3 Cannot update firmware
< User Check >
- Check if other function is being in process.
- Turn the power OFF/ON.
4.14.4 The machine is not turned ON
< User Check >
- Turn the power OFF/ON.
- Properly insert the AC cord.
Step
Cause
Remedy
1
Firmware version does not
match
Reinstall the latest versions of all the
firmwares in the order of the sub firmware,
panel firmware, main firmware, and
high-voltage firmware.
(The panel firmware is available only for the
model with touch panel.)
2
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Connection failure of the
panel PCB harness
Reconnect the panel PCB harness.
2
Connection failure of the LCD
flat cable
Reconnect the LCD flat cable.
3
Connection failure of the
low-voltage power supply
PCB harness
Reconnect the low-voltage power supply
PCB harness.
4
Disconnection of AC cord
Replace the AC cord.
5
Panel PCB failure
Replace the panel PCB unit.
6
LCD failure
Replace the LCD.
7
Low-voltage power supply
PCB failure
Replace the low-voltage power supply PCB
unit.
8
Main PCB failure
Replace the main PCB ASSY.