3-68
Confidential
(3) Remove the two Screw bind M3x8 screws and remove the ADF earth harness and
Document scanner FG harness from the Main PCB plate.
(4) Disconnect the two Connectors (CN39 and CN41) from the Main PCB ASSY and release
the wiring of the Main PCB insulation sheet.
Fig. 3-65
(5) Disconnect the four Connectors (CN20, CN27, CN32 and CN33) and two Flat cables
(CN37 and CN38) from the Main PCB ASSY.
Fig. 3-66
CN39
CN41
Main PCB plate
Document scanner
Main PCB insulation sheet
Main PCB ASSY
FG harness
ADF earth harness
Screw bind M3x8
Screw bind M3x8
Main PCB ASSY
CN3
CN4
CN7
CN13
CN16
CN20
CN27
CN28
CN32
CN33
CN37
CN38
CN41
CN39
CN42
CN43
CN44
CN46
CN47
CN40
CN45 CN30 CN31
CN19
CN18
CN17
CN26
CN15
CN14
CN22
CN9
CN11
CN12
CN10
CN8
CN21
CN6
CN5
CN2
CN49