12. FUNCTION SETTING METHODS
SL-710A
83
12-3. Parameters
The parameter numbers appear on the panel.
Parameter No.10 - 33
Parameter No.
Default value
Data value setting range
Function
10
15 (150 ms)
00 - 25 [X10] (0 - 250 ms)
Time delay from the time the machine starts to operate
with the automatic presser foot raised to the time the
moter operates.
11
05 (50 ms)
03 - 10 [X10] (30 - 100 ms)
Time delay from the time the thread wiper turns OFF
until the automatic presser foot turns ON
12 *1
(From design
change B onward)
03
01 - 10
Time from when lower thread solenoid finally turns
OFF to when motor can operate
13
30 (300 ms)
10 - 90 [X 10] (100 - 900 ms)
Time to keep the automatic presser foot lifter raised
14 (a)
36 (3 min)
00 - 60 [X 5] (5sec - 5 min)
The presser foot signal will be automatically off after the
set time passes. When the data is set to 00, the presser
foot signal is not automatically off.
15 (b)
00 (30ms)
00 - 60 [X 2.5] (0 - 150 ms)
Time from the presser foot lowering command to
when the presser foot momentarily turns ON
16
12
10 - 12
Detection voltage constant from the presser foot
lowering command to when the presser foot
momentarily turns ON
17
10 (10s)
05 - 30 (5 - 30 s)
Continuous puller ON time
18
40 (40 stitches)
00 - 99 (0 - 99 stitches)
Number of stitches from sewing start to lowering of
puller
20
02 (20ms)
01 - 07 [X10] (10 - 70ms)
Time delay from end of thread trimming to the time
when thread wiper turns ON
21
05 (50ms)
04 - 10 [X10] (40 - 100ms)
Thread wiper ON time
22
50 (50ms)
40 - 70 [X1] (40 - 70ms)
Lower thread detect pin ON control time (all areas)
23
10 (10ms)
05 - 25 [X1] (5 - 25ms)
First ON time for lower thread detect pin
24
07 (7ms)
01 - 15 [X1] (1 - 15ms)
First OFF time for lower thread detect pin
26
03 (30ms)
00 - 05 [X10] (0 - 50ms)
Time delay from the time the thread wiper turns OFF to
the time when the lower thread detect pin turns ON
27 (c)
05 (0.5s)
02 - 50 [X0.1] (0.2 - 5.0s)
Time delay from the time when the machine stops
with the needle at its highest/lowest position to the
lower thread detect pin ON (Lower thread detection
function at the needle up/down stop with the foot
pedal in neutral)
30
-04 (-60
°
)
-23 to +23 (units of 15
°
)
(- appears as "-", and +
appears as " ".)
ON timing for quick reverse device during start
backtacking and continuous backtacking
31
00 (0
°
)
-23 to +23 (units of 15
°
)
(- appears as "-", and +
appears as " ".)
OFF timing for quick reverse device during start
backtacking and continuous backtacking
32
+02 (30
°
)
-23 to +23 (units of 15
°
)
(- appears as "-", and +
appears as " ".)
OFF timing for quick reverse device during end
backtacking.
33 (d)
-04 (-60
°
)
-23 to +23 (units of 15
°
)
(- appears as "-", and +
appears as " ".)
2nd ON timing for quick reverse device during
double end backtacking
*1 ... Values are X10 ms.
Notes
(a) The timer-off function for the presser foot is activated only when memory switch 36 is set to off.
(b) The indicated parameters are only enabled when memory switch 35 is set to ON.
(c) The lower thread detection function for the needle up/down stop when the pedal is positioned at neutral is activated
only when memory switch 51is set to on.
(d) The indicated parameters are the settings when memory switch 22 is set to ON.
1834M
Summary of Contents for DB2-DD7100
Page 113: ...21 WIRING DIAGRAMS SL 710A 106 Control circuit board assembly 2 6 1934M ...
Page 114: ...21 WIRING DIAGRAMS SL 710A 107 Control circuit board assembly 3 6 1890M ...
Page 115: ...21 WIRING DIAGRAMS SL 710A 108 Control circuit board assembly 4 6 1891M ...
Page 116: ...21 WIRING DIAGRAMS SL 710A 109 Control circuit board assembly 5 6 1892M ...
Page 117: ...21 WIRING DIAGRAMS SL 710A 110 Control circuit board assembly 6 6 1893M ...
Page 136: ...21 WIRING DIAGRAMS SL 710A 129 21 4 Transformer 1912M ...
Page 137: ...21 WIRING DIAGRAMS SL 710A 130 21 5 Operation panel B 40 Operation panel B 40 1 3 1913M ...
Page 138: ...21 WIRING DIAGRAMS SL 710A 131 Operation panel B 40 2 3 1914M ...
Page 139: ...21 WIRING DIAGRAMS SL 710A 132 Operation panel B 40 3 3 1915M ...
Page 140: ...21 WIRING DIAGRAMS SL 710A 133 21 6 Operation panel B 100 Operation panel B 100 1 3 1916M ...
Page 141: ...21 WIRING DIAGRAMS SL 710A 134 Operation panel B 100 2 3 1917M ...
Page 142: ...21 WIRING DIAGRAMS SL 710A 135 Operation panel B 100 3 3 1918M ...