U
•
Is the synchronizer connector inside
the control box disconnected?
Insert the connector securely.
•
Problem with synchronizer.
Replace the motor.
80
34
UE
•
Is detector pin (1) of the bobbin
thread detector not retracted
correctly?
Retract the detector pin (1).
Use an Allen key to move the
slider (2), and check that the
detector pin (1) moves correctly.
•
Problem with lower thread detector.
Replace the lower thread detector.
Instruction manual
Instruction manual
Uo
•
Is the lower thread detector
connector inside the control box
disconnected?
Insert the connector securely.
•
Is there an open circuit in the
lower thread detector connecting
cord inside the machine head?
Replace the lower thread detector
or the connecting cord.
80
-
0992M
0984M
0982M
1929M
0985M
0993M
0994M
(1)
(2)
Summary of Contents for DB2-DD7100
Page 113: ...21 WIRING DIAGRAMS SL 710A 106 Control circuit board assembly 2 6 1934M ...
Page 114: ...21 WIRING DIAGRAMS SL 710A 107 Control circuit board assembly 3 6 1890M ...
Page 115: ...21 WIRING DIAGRAMS SL 710A 108 Control circuit board assembly 4 6 1891M ...
Page 116: ...21 WIRING DIAGRAMS SL 710A 109 Control circuit board assembly 5 6 1892M ...
Page 117: ...21 WIRING DIAGRAMS SL 710A 110 Control circuit board assembly 6 6 1893M ...
Page 136: ...21 WIRING DIAGRAMS SL 710A 129 21 4 Transformer 1912M ...
Page 137: ...21 WIRING DIAGRAMS SL 710A 130 21 5 Operation panel B 40 Operation panel B 40 1 3 1913M ...
Page 138: ...21 WIRING DIAGRAMS SL 710A 131 Operation panel B 40 2 3 1914M ...
Page 139: ...21 WIRING DIAGRAMS SL 710A 132 Operation panel B 40 3 3 1915M ...
Page 140: ...21 WIRING DIAGRAMS SL 710A 133 21 6 Operation panel B 100 Operation panel B 100 1 3 1916M ...
Page 141: ...21 WIRING DIAGRAMS SL 710A 134 Operation panel B 100 2 3 1917M ...
Page 142: ...21 WIRING DIAGRAMS SL 710A 135 Operation panel B 100 3 3 1918M ...