24
X-VA-MT3809G-MT3810G-eng/541B182AAG/A/2022-10
Brooks Instrument
Installation Manual MT3809G & MT3810G
Section 2 Installation
ÀRZSDWK/RRVHSLHFHVFDQFDXVHREVWUXFWLRQLQVLGHWKH
measurement section of the meter, and potentially even blockage of
WKHPHDVXUHPHQWÀRDWZLWKLQWKHPHDVXUHPHQWWXEH
iii.
)RU(7)(OLQHGPHWHUV
6HOHFWEROWVDQGJDVNHWVFXVWRPHUVXSSO\LQNHHSLQJZLWKWKHÀDQJH
pressure rating or the operating pressure. Also note corrosion
resistance and thermal stability.
Important
WKHLQVLGHGLDPHWHURIWKHÀDQJHVGHYLDWHVIURPWKH
VWDQGDUGGLPHQVLRQV(QODUJHWKHÀDQJHJDVNHWVWRWKHDSSURSULDWH
VL]H$OLJQJDVNHWDQGWLJKWHQQXWVXVLQJWKHWRUTXHVVSHFL¿HGLQ
Table 2-1
Important
: PTFE is deformable under pressure in the cold state. Do
not exceed maximum torque.
G,QVWDOOWKHÀRZPHWHUZLWKLQRIWUXHYHUWLFDO8VHRIDOHYHOLV
recommended to determine the proper alignment.
e. When the process temperature is 300°C / 572°F or above
LQVXODWLRQLVUHTXLUHGRQWKHPHWHUERG\DQGÀDQJHV7KH
insulation is installed between the indicator housing and the
ERG\DQGÀDQJHV'RQRWZUDSWKHLQGLFDWRUZLWKLQVXODWLRQ
Recommended insulation materials are calcium silicate, cellular glass
or mineral wool with a thermal conductivity of .083 W/m-K at 300°C /
572°F.
)LJXUH7\SLFDO%\SDVV,QVWDOODWLRQ
Table 2-1 M
D[LPXP7RUTXHV0RGHO07(7)(
DIN
DN
PN
inch
lb
150lb
300lb
Nm
ft.lbs
15
40
1/2"
150/300
4x M12
4x 1/2"
4x 1/2"
3.4
2.5
25
40
1"
150/300
4x M12
4x 1/2"
4x 5/8"
6.5
4.8
40
40
1,5"
150/300
4x M16
4x 1/2"
4x 3/4"
13.6
10
50
40
2"
150/300
4x M16
4x 5/8"
8x 5/8"
23.6
17.4
DIN
ASME
ASME
Connection size
Stud bolts
Max. torque