Installation Manual MT3809G & MT3810G
Section 2 Installation
How to Remove and Reinstall XP Housing Indicator Covers
Directions to remove and reinstall the XP Housing
,QGLFDWRU&RYHUDGMXVW$ODUPVDQGWKH3RLQWHU
7REHJLQPDNHVXUHWKHÀRDWLVDWUHVWDQGWKHUHLVQ¶WÀRZ
going through the meter.
2. Using your hands or a strap wrench turn the cover counter
clockwise to remove the cover from the housing
3. Remove the cover from the housing. The gasket should stay
attached to the groove in the housing
8VLQJDÀDWEODGHVFUHZGULYHUZLWKDEODGHKROGWKHUHG
alarm pointer and turn the screw counterclockwise to loosen
the pointer, slide it to desired position on scale and tighten
screw.
8VLQJDÀDWEODGHVFUHZGULYHUZLWKDEODGHKROGWKH
pointer and turn the screw to align with the “R” on the scale. It
may take a few adjustments to get the pointer aligned to the
“R”.
6. To replace the cover, place the cover against the housing
and turn the cover clockwise. Note, it will take several rotations
to tighten the cover and the cover must be in contact with the
gasket to keep a watertight seal.