3-8 Using the Remote Function
Every channel of the of the 0152/0154 can be placed in “remote” control.
This means that the flow and setpoint signals can be read and controlled at
remote distance e.g. in a control room. The local setpoint can be changed
but does not have any impact on the connected controller as long as the
controller is “Remote” controlled. When using Volt I/O it is possible to view
the flowrate at the display during remote control. When using mA I/O, this
is not possible.
The remote function will be activated by pushing the
remote button
, When
activated, the display shows “Remote(Volts)” or “Remote (mA)” depending
on the type of I/O.
The flowrate can be shown after confirmation with “Enter”.
The “R” on the display shows that the channel is in “Remote control”.
When using mA I/O the display shows “Remote” only without flow
information. Switching back to local mode again can be done by selecting
“remote (off)” and hitting “Enter”. The channel goes into local control mode
again.