Never use a battery for ignition that is connected to a battery charger.
Always unplug the battery charger before attaching the ignition power cables to the battery.
Never let the striker plate accidentally contact the torch, rods, or work area. Electrical shock and
sparks may result.
The battery can discharge if the striker plate continuously contacts the work area. Exercise caution
to prevent complete discharge of the battery.
Polarity does not matter for ignition since only a direct short is required to ignite the rod.
a. Connect the 15 foot power cable to the torch by firmly seating the black plug in the hole in the back
of the torch assembly then twisting 1/4 turn to lock in place.
b. Connect the other end of the 15 foot power cable to the black battery adapter clamp. Firmly seat
the black plug into the receptacle then twist 1/4 turn to lock in place.
c. Connect the 15 foot striker plate cable to the red battery clamp by firmly seating the red plug into
the receptacle then twisting 1/4 turn to lock it in place.
d. Connect the battery adapter clamps and to the terminals on the 12- or 24-volt DC power source.