FIGURE 31
Unlocking the bail latch
1. Bail latch
NOTE
The bail latch may be attached to either the top or the bottom of the SFP transceiver.
4. Grasp the bail latch and pull the copper or fiber-optic module out of the port.
FIGURE 32
Removing the fiber-optic module
5. Store the copper or fiber-optic module in a safe, static-free place or in an anti-static bag.
6. Install a new copper or fiber-optic module in the port.
Installing a fiber-optic transceiver
You can install a new fiber-optic transceiver in an SFP or SFP+ slot while the device is powered on
and running.
While installing a transceiver, wear an ESD wrist strap with a plug that can be inserted in the ESD
connector on the ICX 7250 device.
DANGER
For safety reasons, the ESD wrist strap should contain a series 1 megaohm resistor.
DANGER
All fiber-optic interfaces use Class 1 lasers.
Perform the following steps to install a fiber-optic transceiver.
Installing a fiber-optic transceiver
70
Brocade ICX 7250 Switch Hardware Installation Guide
53-1003622-02