Brocade FastIron X Series Chassis Hardware Installation Guide
115
53-1001723-02
Monitoring management module redundancy
5
Syntax: show module
The Status column indicates the module status. The management modules can have one of the
following statuses:
•
ACTIVE – The module is currently the active management module.
•
STANDBY – The module is the standby management module. The status of the standby module
can be one of the following:
•
Init – The module is currently initializing as the standby module.
•
OK – The module is ready to take over as the active module, if necessary.
•
Wait – The module is awaiting boot information from the active management module.
•
Sync – The active module is currently synchronizing files between itself and the standby
module.
Displaying temperature information
Each management module contains two temperature sensors. By default, the system polls the
temperature of each management module every 60 seconds. You can display the current
temperature of the management modules (and all other modules) by entering the following
command at any CLI level.
Syntax: show chassis
The output displays the temperature of the management modules. For information about all output
generated by the show chassis command, refer to
FastIron SX 800 Router# show module
Module Status Ports
Starting MAC
F1: SX-FISF Switch Fabric active
F2: SX-FISF Switch Fabric active
S1: SX-F424C 24-port Gig Copper OK 24
00e0.5200.0100
S2:
S3:
S4:
S5: SX-F424C 24-port Gig Copper OK 24
00e0.5200.0160
S6:
S7:
S8:
S9: SX-FI2XGMR4 2-port Management Active 2
00e0.5200.0100
{ Status : OK }
S10: SX-FI2XGMR4 2-port Management Standby 2
00e0.5200.0100
{ Status : OK }
FastIron# show chassis
...
Slot 9 Temperature: 31.0 deg-C
Slot 10 Temperature: 34.0 deg-C
...