WVRC-8 Installation and Operation Manual
INSTALLATION
Name
Type Description
ST1A - 8A
Connector
Status opto-isolators. When configured for DRY (fac-
tory default) this terminal is ground. When configured
for WET (floating), this terminal is the anode via a
2.2K ohm current limiting resistor. (BOTTOM)
ST1B - 8B
Connector
Status opto-isolators. This terminal is always the cath-
ode (BOTTOM)
K1NC - K4NC
Connector
Normally closed, dry relay contacts. Raise function
(TOP)
K1CM - K4CM
Connector
Common (wiper), dry relay contact. Raise function
(TOP)
K1NO - K4NO
Connector
Normally open, dry relay contact. Raise function
(TOP)
K5R - K8R
Connector
Normally open, dry relay contact. Raise function
(TOP)
K5R - K8R
Connector
Common (wiper), dry relay contact. Raise function
(TOP)
K1NC - K4NC
Connector
Normally closed, dry relay contact. Lower function
(BOT)
K1CM - K4CM
Connector
Common (wiper), dry relay contact. Lower function
(BOT)
K1NO - K4NO
Connector
Normally open, dry relay contact. Lower function
(BOT)
K5L - K8L
Connector
Normally open, dry relay contact. Lower function
(BOT)
K5L - K8L
Connector
Common (wiper), dry relay contact. Lower function
(BOT)
CONFIGURE
Dipswitch
Used to configure the unit. Refer to table of contents.
TEMP
3.5mm Jack
Temperature probe input jack. T/R/S.
PF
2.1mm Jack
Power Failure power jack (optically-isolated). 6 - 12
VDC,center positive.
BT-LINK
Dual RJ45’s
RJ45, used for future system expansion.
12VAC
2.1mm Jack
System power supply input. 12 volts AC.
GND
# 6 screw
System ground screw. Tie to station ground system.