Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty Ltd
20
7.1 Sequence of Operation
Check correct sequence of operation, then proceed to instruct customer on correct thermostat operation for refrigerated
cooling. Refer to the thermostat operating instructions. .
Ventilation
Set the thermostat to the fan only mode. The fan only will start and operate continuously.
Cooling
On a call for cooling the compressor and outdoor fan/s will start and cycle in response to the thermostat to maintain the
desired room temperature. The heater’s fan will operate continuously or will cycle with compressor depending on the
selected fan mode.
Fault Lockout
When the high or low pressure limiting switch trips the compressor and outdoor fan/s are disabled. The compressor and
outdoor fan will remain off until the system is reset via thermostat or on/off switch.