Fig. 9 - Indoor Unit Dimensions DI-XU18Z
5.0 OUTDOOR UNIT INSTALLATION
5.1 Location
•
The unit must be installed in accordance with relevant authority requirements.
•
The unit should not be accessible to general public
•
Do not install the unit where there is a possibility it will present a noise problem for either the home owner or
neighbours, or exceed the noise guidelines as set down by local or state legislation or regulatory bodies.
•
Avoid positioning unit in direct sunlight
•
The unit must be installed in an area that is well ventilated - avoid positions where condenser air may be
recirculated
•
Allow for drainage of rainwater
•
Ensure minimum clearances, as outlined in the outdoor unit dimensional drawings (Section 5.5), are maintained
Mounting at ground level:
•
The unit shall be mounted and fastened on to a solid, level foundation
•
Apply rubber “waffle pad” or similar between the unit feet and the foundation if required
Mounting on the roof:
•
Ensure that the weight of the unit is not excessive for the design of the roof structure
•
Unit shall be mounted onto either a suitably designed metal frame or timber blocks, ensuring that there is an
insulating membrane such as rubber “waffle pad” between the roof structure and the frame for vibration
elimination
•
Metal frame or timber supports must be of sufficient size and length to prevent the unit tipping over in high winds.
5.2 Electrical Connection
All electrical work shall be carried out by a qualified and licensed electrician. The installation shall comply with current
relevant standards, wiring rules and local authority requirements. Means for disconnection (i.e. isolating switch and circuit
breaker) shall be incorporated according to wiring rules. Wiring sizing is the responsibility of the installer as it depends on