Ac ce ssi ng dat a vi a P ROFI BUS
44
Operating manual for PROFIBUS fieldbus | 2015-07 | V1.7 EN
PROFIBUS
FKO parameter
Slot
Index
Parameter
Number*
Accepted
Name in
German
Minimum
Maximum
Unit
1
54
54
1,181
2: Always
Auto
acknowledgeme
nt
0
1000
s
1
109
109
1,182
2: Always
Auto ackn. no.
0
500
1
55
55
2,050
2: Always
Fixed frequency
mode
0
4
1
9
9
2,051
2: Always
Fixed frequency
1
-400
400
Hz
1
10
10
2,052
2: Always
Fixed frequency
2
-400
400
Hz
1
11
11
2,053
2: Always
Fixed frequency
3
-400
400
Hz
1
12
12
2,054
2: Always
Fixed frequency
4
-400
400
Hz
1
13
13
2,055
2: Always
Fixed frequency
5
-400
400
Hz
1
14
14
2,056
2: Always
Fixed frequency
6
-400
400
Hz
1
15
15
2,057
2: Always
Fixed frequency
7
-400
400
Hz
1
139
139
2,150
2: Always
MOP digit. input
0
8
1
51
51
2,151
2: Always
MOP step range
0
100
%
1
141
141
2,152
2: Always
MOP step time
0.02
1000
s
1
140
140
2,153
2: Always
MOP react. Time
0.02
1000
s
1
142
142
2,154
2: Always
MOP reference
memory
0
1
1
37
37
3,050
2: Always
PID-P amplific.
0
100
1
38
38
3,051
2: Always
PID-I amplific.
0
100
1/s
1
39
39
3,052
2: Always
PID-D amplific.
0
100
s
1
6
6
3,060
2: Always
PID actual value
0
3
1
82
82
3,061
2: Always
PID inverted
0
1
1
83
83
3,062
2: Always
PID fixed
nominal value 1
0
100
%
1
127
127
3,063
2: Always
PID fixed
nominal value 2
0
100
%
1
128
128
3,064
2: Always
PID fixed
nominal value 3
0
100
%