Ac ce ssi ng dat a vi a P ROFI BUS
50
Operating manual for PROFIBUS fieldbus | 2015-07 | V1.7 EN
PROFIBUS
FKO parameter
Slot
Index
Parameter
Number*
Accepted
Name in
German
Minimum
Maximum
Unit
2
73
329
33,034
1: Ready
Motor speed
0
80000
rpm
2
74
330
33,035
1: Ready
Motor frequency
10
400
Hz
2
115
371
33,050
1: Ready
Stator resistance
0
100
Ohm
2
117
373
33,105
1: Ready
Scatter
inductivity
0
1
H
2
68
324
33,110
1: Ready
Motor voltage
0
1500
V
2
72
328
33,111
1: Ready
Motor cos phi
0.5
1
2
125
381
33,138
2: Always
Holding current
time
0
3600
s
2
116
372
33,200
1: Ready
Stator induc.
0
1
H
2
129
385
33,201
1: Ready
Nominal flux
0
10000
mVs
2
111
367
34,010
1: Ready
Control method
100
299
2
85
341
34,011
1: Ready
Type of encoder
0
2
1
2
86
342
34,012
1: Ready
Encoder line
count
0
10000
1
2
87
343
34,013
2: Always
Encoder offset
-360
360
°
2
131
387
34,020
2: Always
Flying restart
0
1
2
130
386
34,021
2: Always
Catch time
0
10000
ms
2
8
264
34,030
2: Always
Switching
frequency
1
4
2
121
377
34,090
2: Always
Speed controller
Kp
1
10000
mA/rad
/s
2
122
378
34,091
2: Always
Speed controller
Tn
0
10
s
2
113
369
34,110
2: Always
Slip trimmer
0
1.5
2
138
394
34,120
2: Always
Quadr.
characteristic
curve
0
1
2
139
395
34,121
2: Always
Flux adjustment
10
100
%
2
114
370
34,130
2: Always
Control reserve
voltage
0
3
2
137
393
34,225
1: Ready
Field
weaken.PMSM
0
1