Ac ce ssi ng dat a vi a P ROFI BUS
40
Operating manual for PROFIBUS fieldbus | 2015-07 | V1.7 EN
4.2.2 Process data In which can be parameterised
The remaining 4 process variables (2
– 6) can be parameterised with the help
of the FKOpc tool using parameters 6.110 to 6.113. The available process
variables of the parameter settings can be found in the following table.
Consec.
no.
Data type
SW
vers.
Designation
Unit
Description
0
DWORD
*
03.02
Digital relay outputs
1
Control of digital and relay outputs
1
REAL
03.02
Analogue Out 1
V
Control of analogue output
2
DWORD
03.04
Customised
input variable 1
1
Customised input variable Soft
PLC (32 bit)
4
REAL
03.04
Customised
Input variable 2 / PID
actual value
-
Customised input variable Soft
PLC
5
REAL
03.04
Customised
input variable 3
-
Customised input variable Soft
PLC
6
REAL
03.04
Customised
input variable 4
-
Customised input variable Soft
PLC
Tab.: 7 Process data In which can be parameterised
* DWORD data type corresponds to UINT32
=
4 bytes
4.3 Non-cyclic data access / parameters
IMPORTANT INFORMATION
Only parameters with an access level of 2 or less can be accessed
(see list of parameters in operating manual).
Access for both reading and writing is possible.
IMPORTANT INFORMATION
You will find detailed information about the parameters in the
"Parameters" chapter of the "FKO drive controller" operating
manual.