Use and Maintenance Manual – VER. 2016-02
Page 35
By pressing [P8] Start
the machine will run a spin cycle and at the end of this will display the number of shaft
RPMs.
To exit the testing program, press [F+P9]
.
SIG Pick-up signals test
This program allows you to check the pick-up signal. To run the test, you will need to mount a balanced wheel with a steel rim, 15”
in diameter and 6” in width (or as similar as possible) on the machine. A 50-gram weight must be applied on the external side of the
wheel.
By pressing [P8] Start
the machine will run continuous spinning and the pick-up signals to the three attenuation
processes (Attenuation 1, Attenuation 2, Attenuation 4).
To complete the test, press [P10] Stop
or raise the wheel guard.
To exit the testing program, press [F+P9]
.
dPy Display test
The display testing program will light up all the LEDs and the 7-segment displays in sequence so that the operation thereof can be
checked. To turn on all LEDs and display segments in sequence, press [P4]
o [P5]
.
To exit the testing program, press [F+P9]
.
tAS Keypad test
The keypad testing program is used to check the operation of all the keys on the control panel. Every time a key is pressed, its code
appears on the screen: for example, if you press [P8] Start
code “P8” appears, if you press *P10+ Stop
code “P10” appears, and so forth.
The code of the key [P7]
is not displayed.
To exit the testing program, press [F+P9]
.
UFc Converter voltage
–
frequency test
The converter voltage – frequency test shows two numbers on the displays that represent the electronic control board conversion
values.
These values are used by technical support personnel to determine the operational status of the board.
Summary of Contents for VULTURE BP46
Page 1: ...BP46 VULTURE ...