Use and Maintenance Manual – VER. 2016-02
Page 14
1.
Switch on the machine;
2.
Remove the wheel and any other accessories from the shaft;
3.
Press the [F+P3] button
. The words
SER SER
will appear (this means that we have
entered SERVICE mode (service programs);
4.
Press the [P3] button
. The words
CAL TRC
will appear on the screen (machine calibration for truck
wheels);
5.
Use [P4]
or [P5]
to select the type of CAR calibration (auto-vehicle and light off-road wheels).
6.
Press the [P3] button
. The words
CAL 0
will be displayed;
7.
Press the [P8] Start button
. The machine will perform a set of four short spins followed by a complete spin.
At the end the words
CAL 1
will appear on the screen.
8.
Mount the wheel on the shaft and enter the wheel dimensions by pressing the [P1]
, [P2]
,
[P3]
to select the dimensions for editing, and the [P4]
or [P5] keys
to edit the
value. If the dimensions of the wheel have been entered before accessing the calibration program, this step can be
skipped. It is not possible to enter the data with the automatic acquisition system;
9.
Press Start button [P8]
: the machine will run a spin cycle;
10.
At the end of the spin, manually rotate the wheel until the left display shows the value 50. On the inner side of the wheel,
at 12 o'clock, apply the 50 g weight.
11.
Press Start button [P8]
: the machine will run a spin cycle;
12.
Remove the 50 gr. weight applied on the internal side;
13.
At the end of the spin, manually rotate the wheel until the right display shows the value 50. On the outer side of the
wheel, at 12 o'clock, apply the 50 g weight.
14.
Press Start button [P8]
: the machine will run a spin cycle;
15.
Calibration is finished: the machine automatically exits the calibration program and returns to NORMAL mode, ready to
perform balancing.
If you have anomalies during the calibration procedure, the machine will display the error message (for example
ERR 025
). See
section
“21.1 Error codes”
and act accordingly to eliminate the problem and continue/repeat/cancel the calibration in progress.