![BRIGHT VULTURE BP46 Manual Download Page 13](http://html.mh-extra.com/html/bright/vulture-bp46/vulture-bp46_manual_2811764013.webp)
Use and Maintenance Manual – VER. 2016-02
Page 12
15.1 When to carry out machine calibration
Table T15.1 lists the cases in which machine calibration should be carried out. Calibration must be carried out whenever one or
more of the conditions listed are active.
Table T15.1: Conditions for carrying out machine calibration
Condition
Status
Who must perform it
When the machine is installed at the final user's site
Mandatory
Technical Service
When the electronic circuit board is replaced
Mandatory
Technical Service
When a mechanical part linked to the pick-up signal (pick-up, pick-up compression
springs, suspension unit + shaft) is replaced
Mandatory
Technical Service
When the pick-up compression spring adjustment is modified
Mandatory
Technical Service
When the encoder disc is replaced
Mandatory
Technical Service
When a different motorbike adaptor is used since the last calibration for MOTO
Wheel Type
Mandatory
Final
user
and/or
Technical Service
When the machine does not provide the best balancing results
Recommended
Final
user
and/or
Technical Service
When there are large, constant variations in the environmental humidity and
temperature conditions (for example seasonal changes)
Recommended
Final
user
and/or
Technical Service
The machine requires two independent calibrations:
Calibration for the CAR/SUV Wheel Type (calibration is the same for both types of wheel);
Calibration for TRUCK Wheel Type.
15.2 Machine calibration for TRUCK Wheel Type
There is only one type of TRUCK Wheel calibration.
To perform machine calibration, you must first provide for the following material:
A balanced wheel with a steel rim having the following dimensions: Diameter 22.5”. Wheels with dimensions similar to
those specified can also be used provided that the difference is small. It is not possible to use wheels with aluminium rims.
A 300-gram weight (preferably made of Iron or Zinc).
To perform the machine calibration, proceed as follows:
1.
Switch on the machine;
2.
Remove the wheel and any other accessories from the shaft;
3.
Press the [F+P3] button
. The words
SER SER
will be displayed (this means that we have
entered in SERVICE mode (service programs);
4.
Press the [P3] button
. The words
CAL TRC
will appear on the screen (machine calibration for truck
wheels);
5.
Press the [P3] button
. The words
CAL 0
will be displayed;
6.
Press the [P8] Start button
. The machine will perform a set of four short spins followed by a
complete spin.
At the end the words
CAL 1
will appear on the screen.
Summary of Contents for VULTURE BP46