Operating flow rate and pressure requirements for cleaner, Typhoon – 6.0 mm nozzles
Required flow rate
Throughp
ut [m
3
/h]
7.4
8.2
8.9
9.6
10.0
10.3
10.5
[l/min]
123.3 136.7 148.3 160.0 166.7 170.8 175.0
[USgpm]
32.6
36.1
39.2
42.3
44.0
45.1
46.2
Required pressure
[bar]
4.0
5.0
6.0
7.0
8.0
9.0
10.0
[psi]
58.0
72.5
87.0
101.5 116.0 130.5 145.0
Tempest
Operating flow rate and pressure requirements for cleaner, Tempest– 7 mm nozzles
Required flow rate
Throughp
ut [m
3
/h]
12.0
13.7
15.3
16.7
18.0
18.6
19.2
[l/min]
200
227.5 255.0 277.5 300.0 310.0 320.0
[USgpm]
52.8
60.1
67.4
73.3
79.3
81.9
84.5
Required pressure
[bar]
4.0
5.0
6.0
7.0
8.0
9.0
10.0
[psi]
58.0
72.5
87.0
101.5 116.0 130.5 145.0
Operating flow rate and pressure requirements for cleaner, Tempest– 8 mm nozzles
Required flow rate
Throughp
ut [m
3
/h]
13.5
15.8
18.0
19.5
21.0
22.2
23.4
[l/min]
225.0 262.5 300.0 325.0 350.0 370.0 390.0
[USgpm]
59.4
69.3
79.3
85.9
92.5
97.7
103.0
Required pressure
[bar]
4.0
5.0
6.0
7.0
8.0
9.0
10.0
[psi]
58.0
72.5
87.0
101.5 116.0 130.5 145.0
Tornado
Operating flow rate and pressure requirements for cleaner, Tornado – 11 mm nozzles
Required flow rate
Throughp
ut [m
3
/h]
14.6
15.4
16.1
18.3
20.4
21.6
22.7
[l/min]
243.3 255.8 268.3 304.2 340.0 359.2 378.3
[USgpm]
64.3
67.6
70.9
80.4
89.8
94.9
99.9
Required pressure
[bar]
4.0
5.0
6.0
7.0
8.0
9.0
10.0
[psi]
58.0
72.5
87.0
101.5 116.0 130.5 145.0
Tornado 4
Operation and control
Operating Conditions
430BAL011762EN_2
28.05.2018
31