6.4
Removing
Remove in reverse sequence of installation.
Caution!
Hot surface of the cleaner
Danger of burns.
► Allow the cleaner to cool before removing it.
Caution!
Hot and aggressive liquids can be discharged from the cleaner.
Danger of injury.
► Completely drain the cleaner before removing it.
Notice
Danger when unscrewing the cleaner via the lower body
Doing so will cause damage to the gears inside the cleaner or jamming of
the mechanism
► Use the cylindrical upper body as contact point for the tool.
Carry out the following steps:
1.
Use a strap wrench/adjustable spanner on the cylindrical upper body or a
suitably sized spanner on the spanner flats provided to unscrew the cleaner
from the pipe.
Fig.10
2.
Support the lower body (2) and carefully unscrew the cylindrical upper body
(1) by hand until the cleaner comes free from the inlet pipe.
Assembly and installation
Removing
430BAL011762EN_2
26
28.05.2018