6
Assembly and installation
6.1
Safety notes
Hazardous situations during installation can be avoided by safety-conscious and
proactive behaviour of the personnel.
For installation, the following principles apply:
•
Only properly qualified staff is allowed to install, assemble and set the cleaner
into operation.
•
Ensure that adequate working and traffic areas are available at the place of
installation.
•
Observe the maximum load-bearing capacity of the installation surface.
•
Observe the transport instructions and markings on the part(s) to be
transported.
•
Remove any nails protruding from transport crates immediately after opening
the crate.
•
Under no circumstances should anyone stand under a suspended load.
•
During assembly, the cleaner's safety devices might not be working
effectively.
•
Reliably secure sections of the plant which have already been connected
against inadvertently being switched on.
6.2
Notes on installation
Observe the following points before installing the cleaner:
•
Switch off the power circuit and protect it from unauthorized switch-on.
•
Protect the supply pump for CIP medium against unauthorized switch-on.
•
Shut off the cleaning medium supply line and secure the line against being
opened. There must not be any chemical cleaning medium in the supply line.
•
Make sure that there are no foreign objects in the system.
•
Clean (rinse) the cleaning medium supply line before connecting the orbital
cleaner.
•
The electrical installation must be in accordance with the requirements of EN
60079-14 in areas with explosive gas atmosphere and in accordance with the
requirements of EN 61241-4 in areas with explosive dust atmosphere.
6.3
Installation
Prerequisite:
•
We generally recommend that a 500 ϻm filter/strainer should be installed in
the CIP supply line at the tank cleaner to prevent blockage or damage
resulting from foreign particles. It is the customer‘s responsibility to ensure the
suitability of the strainer/filter retention rating for this particular application.
•
The cleaner must have a suitable pipe connection for this.
Assembly and installation
Safety notes
430BAL011762EN_2
24
28.05.2018