Flashing Installation – 

Insert Models 

 

1.

 

After

 

installing

 

the

 

stove

 

in

 

the

 

fireplace,

 

pull

 

the

 

stove

 

toward

 

the

 

hearth

 

just

 

a

 

couple

 

of

 

inches.

 

2.

 

Remove

 

the

 

two

 

screws

 

on

 

each

 

side

 

of

 

the

 

stove

 

using

 

a

 

3/32”

 

allen

 

wrench.

 

3.

 

With

 

the

 

Philips

 

head

 

screws

 

provided

 

install

 

two

 

screws

 

on

 

each

 

side

 

of

 

the

 

stove

 

and

 

only

 

partially

 

tighten.

 

4.

 

Insert

 

the

 

side

 

flashing

 

over

 

the

 

screw

 

head

 

and

 

allow

 

to

 

drop

 

down.

 

5.

 

Tighten

 

Philips

 

head

 

screws.

 

6.

 

Repeat

 

for

 

other

 

side.

 

7.

 

Install

 

two

 

Phillips

 

Head

 

screws

 

in

 

the

 

top

 

of

 

each

 

side

 

flashing

 

and

 

only

 

partially

 

tighten.

 

8.

 

Slide

 

the

 

top

 

flashing

 

onto

 

the

 

screws

 

and

 

tighten

 

screws.

 

9.

 

Push

 

stove

 

and

 

flashing

 

into

 

fireplace

 

so

 

that

 

the

 

flashings

 

align

 

against

 

the

 

face

 

of

 

the

 

hearth.

 

 
 
 

Mobile or Manufactured Home Requirements 

 

NOTE:

  

Not

 

approved

 

for

 

Canadian

 

Mobile

 

Home

 

Installations.

  

These

 

directions

 

only

 

apply

 

for

 

mobile

 

home

 

installations

 

within

 

the

 

United

 

States

 

of

 

America.

 

 

WARNING:

 

DO

 

NOT

 

INSTALL

 

IN

 

A

 

SLEEPING

 

ROOM.

 

 

NOTE:

   

The

 

outside

 

air

 

kit

 

MUST

 

be

 

used

 

(See

 

“OUTSIDE

 

AIR

 

KIT”),

 

and

 

a

 

spark

 

arrestor

 

may

 

be

 

required.

  

Check

 

with

 

your

 

local

 

building

 

officials.

 

 

NOTE:

 

DOUBLE

 

WALL

 

PIPE

 

IS

 

REQUIRED

 

FOR

 

THE

 

EXHAUST.

  

Single

 

wall

 

pipe

 

is

 

NOT

 

authorized

 

for

 

Mobile

 

or

 

Manufactured

 

Home

 

Installations.

 

 

The

 

W3100FS

 

must

 

be

 

securely

 

fastened

 

to

 

the

 

floor

 

of

 

the

 

mobile

 

(manufactured)

 

home

 

using

 

the

 

mounting

 

bolt

 

holes

 

located

 

in

 

the

 

pedestal

 

of

 

the

 

W3100FS.

 

Use

 

only

 

the

 

holes

 

provided.

 

 

If

 

the

 

optional

 

blower

 

is

 

used

 

the

 

W3100FS

 

must

 

be

 

grounded

 

to

 

the

 

steel

 

chassis

 

of

 

the

 

home

 

with

 

8

 

Ga.

 

Copper

 

wire

 

using

 

a

 

serrated

 

or

 

star

 

washer

 

to

 

penetrate

 

paint

 

or

 

protective

 

coating

 

to

 

ensure

 

grounding.

 

 

CAUTION:

 

DURING

 

THE

 

INSTALLATION

 

OF

 

THIS

 

STOVE,

 

DO

 

NOT

 

COMPROMISE

 

THE

 

STRUCTUARL

 

INTEGRITY

 

OF

 

THE

 

MOBILE

 

(MANUFACTURED)

 

HOME

 

WALL(S),

 

FLOOR

 

OR

 

CEILING.

 

 

Summary of Contents for Mahogany W3100I

Page 1: ...ials about restrictions and installation inspection requirements in your area Local regulations and requirements can supersede those specified in this manual if more stringent PLEASE read this entire...

Page 2: ...Outside Air Kit FS Pedestal Units 11 Outside Air Kit FS Leg Units 12 Flashing Installation Insert Models 13 Mobile or Manufactured Home Requirements 13 Installing the Brick Panels 14 Freestanding Ins...

Page 3: ...or debris off of the stove before firing The paint will become soft and gummy as the stove heats up and will harden as the stove cools During the break in period open the door frequently every 5 10 mi...

Page 4: ...is stove as well The exhaust system must be completely airtight and properly installed This unit must be properly installed to prevent the possibility of a house fire The instructions must be strictly...

Page 5: ...operating the heater WARNING DO NOT OPERATE HEATER WITH THE GLASS PANEL REMOVED CRACKED OR BROKEN REPLACEMENT OF THE PANEL SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON Ensure adequate com...

Page 6: ...Pedestal 37 1 8 to Front Height with Large Flashing 32 1 16 38 13 16 to Shroud Height with Medium Flashing 30 1 16 Height with Standard Pedestal 31 1 4 to Front Height of unit inside fireplace 20 1 2...

Page 7: ...listed to the pipe Insert Model Minimum Clearances to combustibles must be maintained as shown in the following chart NOTE Materials projecting more than from the wall are considered mantels I J K L...

Page 8: ...that it either be cemented to the masonry or be installed without cement in a thimble connected to the masonry wall When the connector is inserted in a thimble the joint must be tight enough so that i...

Page 9: ...36 of the front of the stove 4 Clearances All specified clearances to combustibles must be maintained Measurements provided are the minimum safe distances and should not be compromised 5 Chimney Termi...

Page 10: ...not fully remove realign the stove and firmly retighten the bolts NOTE For units with the pedestal only no ash pan or wood storage the stove will have to be lifted straight up for pedestal installatio...

Page 11: ...sher and partially tighten 3 Hold the blower on both sides and allow the screw heads to go through the slots and move the blower to the right as much as possible 4 Tighten bolts with 7 16 wrench 5 Rou...

Page 12: ...minimum clearances are met position the stove on the floor protection Draw an outline around the pedestal on the floor protector Remove the stove 2 In the center of the outline of the pedestal foot pr...

Page 13: ...with a screen and seal to the floor 8 Reposition the hearth pad and the stove so that the Rectangular Air Chamber is aligned with hole in the hearth pad 9 Secure the Rectangular Air Chamber to the Upp...

Page 14: ...quirements NOTE Not approved for Canadian Mobile Home Installations These directions only apply for mobile home installations within the United States of America WARNING DO NOT INSTALL IN A SLEEPING R...

Page 15: ...d when handling the brick panels Install the brick panels shown in figure 6 in the following order C B A and F Next remove the front secondary tube Install the panels D with the ceriblanket above them...

Page 16: ...re than 180o of elbows two 90o elbows or two 45o one 90o elbow etc Standard residential installations may use single wall connector Mobile Home may NOT Standard residential installations with reduced...

Page 17: ...lation Freestanding with Exterior Factory Built Chimney NOTE Exterior chimneys are subject to greater moisture and creosote accumulation due to the lower temperatures An insulated chase can help to re...

Page 18: ...ding with Masonry or Factory Built Chimney NOTE Most factory built chimney manufacturers make stainless steel chimney liners either flexible or rigid This provides a wide variety of installation optio...

Page 19: ...e including chimney must be clean and undamaged Any damage must be repaired prior to installation of the insert All convection vents and louvers must be left unmodified and unobstructed Entire firepla...

Page 20: ...d edges 2 Make a cardboard template of the measurements but add a 2 flange to each side This flange will be used to mount the block off plate to the inside of the firebox Bend the flanges downwards on...

Page 21: ...ONS This fireplace insert must be installed with a continuous chimney liner of 6 diameter extending from the fireplace insert to the top of the chimney The chimney liner must conform to the Class 3 re...

Page 22: ...Direct Connection Zero Clearance Fireplace NOTE Direct connections require installation of an airtight block off plate or damper adaptor see Block off Plate Installation on page 16 Although this inst...

Page 23: ...ncreasing sizes of wood before adding larger pieces for longer burns Always allow enough time for the wood to get burning well before adding larger pieces of wood When loading wood always be careful n...

Page 24: ...ugh to burn efficiently but this will now take less pre heating than older stoves After some initial experimentation you will be able to determine the optimum operating temperatures for various burn r...

Page 25: ...ever use substitute materials Chimney Cleaning Inspection Before each heating season the entire chimney system combustion chamber and fireplace should be professionally inspected cleaned and if necess...

Page 26: ...e test the wood with a moisture meter Some experienced wood burners can measure wood moisture by knocking pieces together and listening for a clear knock and not a thud Why Dry Wood is Key Wet wood wh...

Page 27: ...ing the Door Gasket The door gasket inserts into the outer groove of the door retainer Stove gasket cement holds it in place Before installing remove any residual cement Lay the gasket in place start...

Page 28: ...onal A E 3100BLOWKIT Brick Panel Set A BRICK W31 Damper Knob C S 852 Door Gasket C G 050 Door Glass C D 038 Door Handle Shaft CW D 031 Door Handle Wood CW M 250 Glass C D 038 Glass Clip C S 110 Glass...

Page 29: ...the dealer must examine the stove at the consumer s residence a reasonable service call charge may be incurred and is the sole responsibility of the consumer d If the unit must be transported those ch...

Reviews: