Page 19
Lift Installation Instructions
1/4-14 x 1" Washer Hex Head Self-Drilling Screws
Flush Mount
Bracket
28755
100 Amp.
Circuit
Breaker
28704
A
Mount the circuit breaker to the mounting bracket.
Four .191" diameter holes spaced 1" apart are
provided in each mounting bracket. The holes
match the pattern of circuit breaker mounting holes.
Place the bracket securely in a vice gripping the
edge that does not obstruct positioning of the circuit
breaker (see Photo A). Mount the breaker to the
bracket using two 1/4-14 x 1" washer hex head self-drilling
screws.
#8-18 x 3/4" wafer head self-drilling screws are supplied to
mount the circuit breaker and mounting bracket assembly.
Photos B and C depict the flush mount bracket (without
offset) mounted in the engine compartment of a Dodge van.
Two self-drilling screws mount the bracket.
Photos D and E depict the offset bracket mounted in the
engine compartment of a Ford van. One self-drilling screw
and one OEM bolt are used to mount the bracket. Mount
the bracket as needed.
Check for obstructions
such as
fuel lines, coolant lines, wires, exhaust, etc.
before drilling
.
Remove the rubber caps attached to circuit breaker termi-
nals. Attach the lift power cable to the
Auxiliary
terminal of
the Circuit Sentry. Attach one end of the battery lead cable
to the Circuit Sentry
Battery
terminal. Tighten securely.
Reposition the rubber caps onto the breaker terminals to
prevent electrical short circuits.
Carefully
connect the
opposite end of the battery lead cable to the
Positive
(+)
post of the battery.
Dodge
Van Installation
Attach lift (or other device) power cable
to Circuit Sentry
Auxiliary
terminal.
Attach battery lead cable to
Circuit Sentry
Battery
terminal.
#8-18 x 3/4" Wafer Head Self Drilling Screws
Ford
Van Installation
Attach battery lead cable to
Circuit Sentry
Battery
terminal.
Attach power cable to Circuit
Sentry
Auxiliary
terminal.
OEM Bolt
#8-18 x 3/4" Wafer Head
Self Drilling Screw
Decal 18181
B
C
D
E
Post decal 18181
adjacent to the
Circuit Sentry
assembly (provides
circuit breaker reset
instructions).
Note:
Clean the surface
with isopropyl
alcohol
before
decal
application. Use a
clean cloth or paper
towels.
DO NOT
use oily shop rags.
Wipe surface free of
residue with dry
portion of cleaning
cloth.